Veterinary MedicineInfectious DiseasesEarly DetectionHealth Technology AssessmentPatient SafetyDiagnostic EvaluationDiagnostic Test EvaluationRespiratory Pathogen DiagnosticsClinical Data ValidationClinical Sample ProcessingCoronavirus DiagnosticsDiagnostic Accuracy StudiesDiagnostic Testing AccuracyMulticenter ValidationSars-cov-2 InfectionTertiary Care Organization
Importance: Three-dimensionally printed nasopharyngeal swabs (3DP swabs) have been used to mitigate swab shortages during the coronavirus disease 2019 (COVID-19) pandemic. Clinical validation for diagnostic accuracy and consistency, as well as patient acceptability, is crucial to evaluate the swab's performance. Objective: To determine the accuracy and acceptability of the 3DP swab for identifying severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Design, Setting, and Participants: A diagnostic study was conducted from May to July 2020 at 2 tertiary care centers in Singapore with different reference swabs (FLOQSwab [COPAN Diagnostics] or Dacron swab [Deltalab]) and swab processing techniques (wet or dry) to evaluate the performance of the 3DP swab compared with traditional, standard-of-care nasopharyngeal swabs used in health care institutions. The participants were patients with COVID-19 in the first 2 weeks of illness and controls with acute respiratory illness with negative test results for SARS-CoV-2. Paired nasopharyngeal swabs were obtained from the same nostril and tested for SARS-CoV-2 by reverse-transcriptase polymerase chain reaction. The sequence of swabs was randomized based on odd and even participant numbers. Main Outcomes and Measures: Primary outcome measures were overall agreement (OA), positive percentage agreement (PPA), and negative percentage agreement of the 3DP swab compared with reference swabs. Secondary outcome measures were the correlation of cycle threshold (Ct) values of both swabs. Results: The mean (SD) age of participants was 45.4 (13.1) years, and most participants were men (87 of 89 [97.8%]), in keeping with the epidemiology of the COVID-19 pandemic in Singapore. A total of 79 patients with COVID-19 and 10 controls were recruited. Among the patients with COVID-19, the overall agreement and PPA of the 3DP swab was 91.1% and 93.5%, respectively, compared with reference swabs. The PPA was 100% for patients with COVID-19 who were tested within the first week of illness. All controls tested negative. The reverse-transcriptase polymerase chain reaction Ct values for the ORF1ab and E-gene targets showed a strong correlation (intraclass correlations coefficient, 0.869-0.920) between the 3DP and reference swab on independent testing at each institution despite differences in sample processing. Discordant results for both gene targets were observed only at high Ct values. Conclusions and Relevance: In this diagnostic study of 79 patients with COVID-19 and 10 controls, the 3DP swab performed accurately and consistently across health care institutions and could help mitigate strained resources in the escalating COVID-19 pandemic.
13
Bernard La Scola, Marion Le Bideau, Julien Andréani et al. · European Journal of Clinical Microbiology & Infectious Diseases · 2020 · 896 citations · Full text
Evaluation of COVID-19 RT-qPCR Test in Multi sample Pools
Idan Yelin, Noga Aharony, Einat Shaer Tamar et al. · Clinical Infectious Diseases · 2020 · 452 citations · Full text
Cody Callahan, Rose Lee, Katelyn E. Zulauf et al. · Journal of Clinical Microbiology · 2020 · 137 citations · Full text