Abstract X-ray photodetection are frequently used in medical diagnoses industrial inspection and environmental radiation detection. Currently, there is an ongoing effort to develop bendable or flexible x-ray photodetectors (PDs) to meet the demand on light weight and arbitrary shape detection system. Here, a highly bendable indirect x-ray PD is designed by coupling a P3HT:PC 61 BM organic photodetectors (OPDs) with a flexible perovskite quantum dots (QDs) embedded polymer scintillator. The flexible perovskite QDs scintillator exhibits high radioluminescence with emission peak centers at the 537 nm, which falls in maximum absorption range of poly(3-hexylthiophene) (P3HT). The OPD, with <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mn>2</mml:mn> <mml:mi>μ</mml:mi> <mml:mrow> <mml:mtext>m </mml:mtext> </mml:mrow> </mml:math> active layer, exhibits low dark currents in the range of tens of nanoampere per square centimeter over a wide reversed biased range. The OPD demonstrates detectable light signal down to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mtext>0</mml:mtext> </mml:mrow> <mml:mrow> <mml:mtext>.1</mml:mtext> </mml:mrow> <mml:mi>μ</mml:mi> <mml:mrow> <mml:mtext>W</mml:mtext> </mml:mrow> <mml:mrow> <mml:mtext>cm</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext> </mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> and low dose detection capability. The coupling of perovskite QDs scintillator and OPD shows a sensitivity of 638 e nGy −1 mm −2 <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mfenced close=")" open="("> <mml:mrow> <mml:mrow> <mml:mtext>10</mml:mtext> </mml:mrow> <mml:mrow> <mml:mtext>.2 </mml:mtext> </mml:mrow> <mml:mi>μ</mml:mi> <mml:mrow> <mml:mtext>C G</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>y</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mrow> <mml:mtext>1</mml:mtext> </mml:mrow> </mml:mrow> </mml:msup> </mml:mrow> <mml:mrow> <mml:mtext> c</mml:mtext> </mml:mrow> <mml:mrow> <mml:msup> <mml:mrow> <mml:mtext>m</mml:mtext> </mml:mrow> <mml:mrow> <mml:mo>−</mml:mo> <mml:mrow> <mml:mtext>2</mml:mtext> </mml:mrow> </mml:mrow> </mml:msup> </mml:mrow> </mml:mrow> </mml:mfenced> </mml:math> at a dose rate of 1 mGy s −1 , which brings the possibilities of realizing highly bendable x-ray PDs.

References

36