Clinical Oral Implants Research · 2021 · 10 citations · 22 references
DentistryImplant DentistryOral SurgeryDigital Implant DentistryImplant SurgeryProstheticsGuided Implant SurgeryImplant DesignImplant Prosthesis DesignImplant Treatment PlanningMaxillofacial Prosthesis FabricationTreatment Planning For Implant ProsthesesComputer-aided Implant Prosthesis DesignComputer-aided Implant Prosthesis FabricationComputer-aided Prosthetic DesignDigital Treatment WorkflowImplant Prosthetic PlanningProvisional Implant-supported ProsthesesStatic Computer-aided Implant SurgeryStatic Computer-guided Implant Surgery
OBJECTIVES: Evaluation of seating accuracy of implant immediate provisional prostheses fabricated prior to fully guided static computer-assisted implant surgery (sCAIS). MATERIALS AND METHODS: Two maxillary training models were used to plan for single anterior (S-Ant) and single posterior (S-Post) implant prostheses, and a bridge (B) spanning from an anterior implant (B-Ant) to a posterior implant (B-Post). A commercial software was used to plan the implant location, design the surgical guides and design the provisional prostheses. The master models with the provisional prostheses were scanned to generate virtual master models. For each maxillary model, a total of 10 guides and 10 surgical models were produced. Following implant placements in each surgical model, the provisional prostheses were attached to the implants and were scanned to produce virtual surgical models. The virtual master and surgical models were superimposed to measure the vertical error, the proximal contact error and the proximal contact quality. RESULTS: The vertical error was greatest for the S-Post (0.41 mm), followed by B-Post (0.29 mm), B-Ant (0.26 mm) and S-Ant (0.21 mm). There was no significant difference in vertical errors among the prostheses. For the proximal contact, the S-Ant had significantly greater error (0.45 mm - 0.46 mm) than S-Post (0.15 mm) and B (0.09 mm - 0.15 mm). A similar pattern was observed for proximal contact quality. CONCLUSIONS: All prostheses were associated with errors vertically and at the proximal contacts. Therefore, the clinicians who plan to use this workflow should be prepared to adjust the prosthesis after implant insertion.
22
Faris Younes, Jan Cosyn, Thomas De Bruyckere et al. · Journal Of Clinical Periodontology · 2018 · 192 citations
Wiebe Derksen, Daniël Wismeijer, Tabea Flügge et al. · Clinical Oral Implants Research · 2019 · 153 citations
Karim El Kholy, Simone F. M. Janner, Martin Schimmel et al. · Clinical Implant Dentistry and Related Research · 2018 · 150 citations
Ai Komiyama, Björn Klinge, Margareta Hultin · Clinical Oral Implants Research · 2008 · 133 citations