IEEE Sensors Journal · 2021 · 12 citations · 37 references
Natural SciencesMaterials EngineeringMaterials ScienceElectrochemistryNanomaterialsSensorsChemical SensorsElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsElectrode MaterialsSensor MaterialsCarbon ElectrodesCarbon Paste ElectrodesElectrochemical BiosensingElectrochemical Enzyme SensorsOxidation
We present newly developed electrochemical sensors based on screen-printed carbon electrodes functionalized with HO-BiONO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> , polyethylene glycol coated HO-BiONO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> , and Bi <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">7</sub> NO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> . The performance of these sensors has been studied by cyclic voltammetry experiments and compared in terms of the kinetic rate constant, the sensitivity, and the limit of detection. The polyethylene glycol coated HO-BiONO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> sensor was found with higher oxidation peak current, lower oxidation peak potential, and assured a faster paracetamol reaction due to a higher kinetic rate constant of 42.0 ± 9.8 ms <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> . This sensor also possessed lesser peak-to-peak separation (ΔE <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">p</sub> ) of 243 ± 10 mV with a higher chance of reversible reaction compared to other developed sensors. The polyethylene glycol coated HO-BiONO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> sensor also registered a sensitivity of 43.50 ± 0.54 μA/mM with a relative standard deviation of 1.24 %, which is more than double compared to the bare screen-printed electrode with a limit of detection of 2.24 ± 0.03 μM (R <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> = 0.998, n = 3). HO-BiONO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> and Bi <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">7</sub> NO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> sensors also performed much better with slightly higher kinetic rate constant and higher sensitivity than the bare screen-printed electrode sensor.
37
Electrochemical methods, fundamentals and applications
D.A. Aikens · Journal of Chemical Education · 1983 · 3.2K citations
Bismuth-Coated Carbon Electrodes for Anodic Stripping Voltammetry
Joseph Wang, Jianmin Lu, Samo B. Hočevar et al. · Analytical Chemistry · 2000 · 998 citations
Jan Mocák, Alan M. Bond, S. Mitchell et al. · Pure and Applied Chemistry · 1997 · 898 citations · Full text