Scandinavian Journal of Gastroenterology · 2021 · 17 citations · 35 references
MedicineClinical SciencesOncologyDiagnostic ImagingGastroenterologyUltrasonographyAbdominal UltrasonographyEndoscopic Biopsy TechniquesGastrointestinal EndoscopyGastrointestinal ImagingPancreatic PathologyUltrasound-guided ProceduresDiagnostic Accuracy StudiesEndoscopic UltrasonographyEndoscopic Ultrasound-guided BiopsyEndoscopic Ultrasound-guided Fine-needle AspirationEndoscopic Ultrasound-guided FnaEndoscopic Ultrasound-guided Tissue SamplingNeedle Biopsy TechniqueRetrospective Case Study
BACKGROUND AND AIM: Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is influenced by several factors, primarily operator expertise. Formal training in EUS-FNA, as suggested by the European Society of Gastrointestinal Endoscopy and the American Society for Gastrointestinal Endoscopy guidelines, is not always available and is often expensive and time-consuming. In this study we evaluate factors influencing the diagnostic accuracy of pancreatic EUS-FNA. METHODS: In a retrospective study, 557 consecutive EUS-FNAs were evaluated. Several variables relating to the procedures were considered to calculate the EUS-FNA performance over eight years. RESULTS: A total of 308 out of 557 EUS-FNAs were selected. Overall sensitivity of EUS-FNA was 66% (95% CI: 60.8-71.8), specificity 100%, and diagnostic accuracy 69% (95% CI: 64.0-74.4). An increase in diagnostic accuracy was observed to >90% using a new fine-needle biopsy (FNB) needle and in the case of simultaneous sampling of primary and metastatic lesions. Diagnostic accuracy >80% was observed after 250 procedures, in the absence of rapid on-site cytopathological examination (ROSE). Multivariate logistic regression analysis confirmed that the FNB needle, operator skill, and double EUS-FNA sampling are associated with high diagnostic accuracy. CONCLUSIONS: The learning curve for EUS-FNA may be longer and a considerable number of procedures are needed to achieve high diagnostic accuracy in the absence of ROSE. However, the use of FNB needles and the simultaneous sampling of primary and metastatic lesions can rapidly improve the diagnostic accuracy of the procedure.
35
Marcin Polkowski, Christian Jenssen, Philip Kaye et al. · Endoscopy · 2017 · 363 citations · Full text
Julio Iglesias‐García, J. Enrique Domínguez‐Muñoz, Ihab Abdulkader et al. · The American Journal of Gastroenterology · 2011 · 353 citations · Full text
Jean‐Marc Dumonceau, Pierre H. Deprez, Christian Jenssen et al. · Endoscopy · 2017 · 346 citations · Full text
Medicine, Pathology, Cytopathology +16