ACS Sensors · 2021 · 42 citations · 33 references
MedicineBiomedical EngineeringCardiologyBiosensorsHemostasisMolecular DiagnosticsBioanalytical Method ValidationCardiac BiomarkersClinical AnalysisPoint-of-care Diagnostic DevicesAcute Myocardial Infarction DiagnosisCardiovascular Biomarker DetectionMyocardial Infarction DetectionPaper-based Analytical DevicesPaper-based Diagnostic DevicesTroponin ElevationWhole Blood CollectionWhole Blood Separation
This work introduces the procedure of using non-immunoassay distance-based paper analytical devices (dPADs) to accurately measure any traces of the cardiac troponin I (TnI) in whole blood samples without the use of any external blood separation. This enables a rapid clinical diagnosis and the subsequent follow-up in regard to identifying acute myocardial infarction. These dPADs are designed and constructed to accommodate three parts: (1) a blood separation zone that is immobilized with a hemostatic agent, this no longer requires a blood separation membrane for the isolation of the plasma from the blood element, (2) a pretreatment zone, and (3) a detection zone coated with thymol blue. The quantitative TnI level in the whole blood was determined by measuring the blue color length found in the detection zone, which is proportional to the concentration, owing to the dry protein binding principle. Correspondingly, a mere single drop of human whole blood performs adequately within our proposed method. This reduces both the size of the collection process and the sample volumes needed in the respective medical fields. As we cover all of the optimization studies, our dPADs provide an evaluation of the linearity range from 0.025 to 2.5 ng/mL (R2 = 0.9989) of TnI, with a detection limit as low as 0.025 ng/mL by use of an observation just using the naked eye. To validate the clinical utilities of our proposed method, our dPADs were then applied for the detection of TnI in humans using the whole blood sample of 15 volunteers. A great amount of accuracy was required in this assay because there was no significant difference between both methods, with the confidence level being as high as 95%. This technique also showed that the recoveries ranged from 99.40 to 104.27%, with the highest relative standard deviation being at 3.77%. Thus, our proposed dPADs offer more benefits for a rapid TnI determination.
33
Association of Cardiac Injury With Mortality in Hospitalized Patients With COVID-19 in Wuhan, China
Shaobo Shi, Mu Qin, Bo Shen et al. · JAMA Cardiology · 2020 · 4.5K citations · Full text
Clinical characteristics of 113 deceased patients with coronavirus disease 2019: retrospective study
Tao Chen, Di Wu, Huilong Chen et al. · BMJ · 2020 · 4.2K citations · Full text
Simple, distance-based measurement for paper analytical devices
David M. Cate, Wijitar Dungchai, Josephine C. Cunningham et al. · Lab on a Chip · 2013 · 347 citations
Effects of chitin and chitosan on blood coagulation
Yasuhiro Okamoto, Reina Yano, K Miyatake et al. · Carbohydrate Polymers · 2003 · 305 citations