MDPI (MDPI AG) · 2020 · 13 citations · 28 references
Veterinary MedicineImmunologyInfectious DiseasesDiagnostic MicrobiologyImmunotechnologyMolecular DiagnosticsAntigen Detection AssaysDisease DetectionNanomaterial-based BiosensorsNanoparticle-based ImmunotechnologySerological DiagnosisSerological DiagnosticsAntibody Detection TestsBrucella DetectionGold Nanoparticle DetectionImmunodiagnostic AssaysImmunological AssaysNanoparticle ConjugationNanoparticle-based ImmunoassaysQuantum Dot Signal Amplification
In this article, we describe an immunochromatographic test system developed for rapid serodiagnostics of cattle brucellosis using two markers: Gold nanoparticles (GNPs) and quantum dots (QDs). The test system was compared with immunochromatographic serodiagnostics systems that use only one marker. The approbation of the test system was conducted on samples of cattle sera with low, but diagnostically significant titers of specific antibodies. We show that when two conjugates are used, the intensity of the detectable signal increases by 2&ndash
28
Pilar M. Muñoz, C. M. Marín, Daniel Monreal et al. · Clinical and Vaccine Immunology · 2005 · 151 citations · Full text
Veterinary Medicine, Infectious Diseases, Veterinary Microbiology +17