Clinical Hemorheology and Microcirculation · 2021 · 11 citations · 52 references
MedicineComputational EngineeringSurgeryComputational Fluid DynamicsSurgical InstrumentationVascular SurgeryAneurysm RepairAortic DiseaseAortic SurgeryEndovascular SurgeryHemodynamicsFluid Flow PatternsPulsatile FlowWall Shear Stress
PURPOSE: Cross limb stent graft (SG) configuration technique for endovascular aneurysm repair (EVAR) is employed for splayed aortic bifurcations to avoid device kinking and smoothen cannulation. The present study investigates three types of stent graft (SG) configurations for endovascular aneurysm repair (EVAR) in abdominal aortic aneurysm. A computational fluid dynamic analysis was performed on the pulsatile non-Newtonian flow characteristics in three ideally modeled geometries of abdominal aortic (AA) SG configurations. METHODS: The three planar and crosslimb SG configurations were ideally modeled, namely, top-down nonballet-type, top-down ballet-type, and bottom-up nonballet-type configurations. In top-down SG configuration, most of the device is deployed in the main body in the vicinity of renal artery and the limbs are extended to the iliac artery. While in the bottom-up configuration, some of the SG device is deployed in the main body, the limbs are deployed in aortic bifurcation, and the extra stent graft of the main body is extended to the proximal aorta until the below of the renal artery. The effects of non-Newtonian pulsatile flow on the wall stresses and flow patterns of the three models were investigated and compared. Moreover, the average wall shear stress (AWSS), oscillatory shear stress index (OSI), absolute helicity, pressure distribution, graft displacement and flow visualization plots were analyzed. RESULTS: The top-down ballet-type showed less branch blockage effect than the top-down nonballet-type models. Furthermore, the top-down ballet-type configuration showed an increased tendency to sustain high WSS and higher helicity characteristics than that of the bottom-up and top-down non-ballet type configurations. However, displacement forces of the top-down ballet-type configuration were 40% and 9.6% higher than those of the bottom-up and top-down nonballet-type configurations, respectively. CONCLUSIONS: Some complications such as graft tearing, thrombus formation, limb disconnection during long term follow up periods might be relevant to hemodynamic characteristics according to the configurations of EVAR. Hence, the reported data required to be validated with the clinical results.
52
Heart Disease and Stroke Statistics—2019 Update: A Report From the American Heart Association
Emelia J. Benjamin, Paul Muntner, Álvaro Alonso et al. · Circulation · 2019 · 9.1K citations · Full text
David N. Ku, Don P. Giddens, Christopher K. Zarins et al. · Arteriosclerosis An Official Journal of the American Heart Association Inc · 1985 · 2.7K citations · Full text
Joseph E. Bavaria, Jehangir J. Appoo, Michel S. Makaroun et al. · Journal of Thoracic and Cardiovascular Surgery · 2007 · 575 citations · Full text
Medicine, Cardiology, Surgery +16