European Journal of Dentistry · 2021 · 16 citations · 30 references
DentistryDental Biomaterials ScienceMaterials EngineeringDental MaterialsMechanical Properties Of Dental MaterialsSurface Properties Of Dental MaterialsBiocompatibility Of Dental MaterialsCeramic BiomaterialsImplant MaterialsImplantable BiomaterialsSurface Modification Of ImplantsBiocompatibility Of Dental ImplantsDental Implant MaterialsDental ImplantsMagnetron SputteringSubstrate AdhesionSubstrate Surface PreparationTitanium Implant MaterialsTitanium Materials
Abstract Objectives Dental implant is a revolution in dentistry; some shortages are still a focus of research. This study use long duration of radiofrequency (RF)–magnetron sputtering to coat titanium (Ti) implant with hydroxyapatite (HA) to obtain a uniform, strongly adhered in a few micrometers in thickness. Materials and Methods Two types of substrates, discs and root form cylinders were prepared using a grade 1 commercially pure (CP) Ti rod. A RF–magnetron sputtering device was used to coat specimens with HA. Magnetron sputtering was set at 150 W for 22 hours at 100°C under continuous argon gas flow and substrate rotation at 10 rpm. Coat properties were evaluated via field emission scanning electron microscopy (FESEM), scanning electron microscopy–energy dispersive X-ray (EDX) analysis, atomic force microscopy, and Vickers hardness (VH). Student’s t-test was used. Results All FESEM images showed a homogeneous, continuous, and crack-free HA coat with a rough surface. EDX analysis revealed inclusion of HA particles within the substrate surface in a calcium (Ca)/phosphorus (P) ratio (16.58/11.31) close to that of HA. Elemental and EDX analyses showed Ca, Ti, P, and oxygen within Ti. The FESEM views at a cross-section of the substrate showed an average of 7 µm coat thickness. Moreover, these images revealed a dense, compact, and uniform continuous adhesion between the coat layer and the substrate. Roughness result indicated highly significant difference between uncoated Ti and HA coat (p-value < 0.05). A significant improvement in the VH value was observed when coat hardness was compared with the Ti substrate hardness (p-value < 0.05). Conclusion Prolonged magnetron sputtering successfully coat Ti dental implants with HA in micrometers thickness which is well adhered essentially in excellent osseointegration.
30
Hydroxyapatite-coated Ti–6Al–4V
A.K. Lynn, D.L. DuQuesnay · Biomaterials · 2002 · 129 citations
Roman A. Surmenev, E. V. Shesterikov, M. A. Ryabtseva et al. · Surface and Coatings Technology · 2008 · 117 citations
Natural Sciences, Materials Engineering, Materials Science +15