Energies · 2020 · 25 citations · 33 references
EngineeringElectrical EngineeringElectric MachinesMotor DevelopmentPower ElectronicsDiagnosisDiagnosticsElectrical System DiagnosticsFault DetectionFault DiagnosisInduction MachinesCore SaturationElectric Motor Fault DiagnosisFinite Element ModelingMachine Fault DiagnosisMagnetic SaturationMagnetic Saturation EffectsMotor Fault DiagnosisVoltage
This paper presents some considerations regarding the application of the stator zero-sequence current component (ZSC) in the fault detection of cage induction machines, including the effects of magnetic core saturation. Faults such as rotor cage asymmetry and static, dynamic, and mixed eccentricity were considered. The research started by developing a harmonic motor model, which allowed us to obtain a voltage equation for the zero-sequence current component. The equation allowed us to extract formulas of typical frequencies for particular fault types. Next, in order to verify the effectiveness of ZSC in induction motor fault diagnosis, finite element calculations and laboratory tests were carried out for the previously mentioned faults for delta and wye connections with neutral wire stator winding configurations.
33
Advances in Diagnostic Techniques for Induction Machines
A. Bellini, F. Filippetti, C. Tassoni et al. · IEEE Transactions on Industrial Electronics · 2008 · 1.1K citations · Full text
Engineering, Electrical Engineering, Diagnostic Reasoning +15
Review of Electromagnetic Vibration in Electrical Machines
Xueping Xu, Qinkai Han, Fulei Chu · Energies · 2018 · 102 citations · Full text