2020 · 11 citations · 42 references
EngineeringComputer ScienceComputer SystemsDistributed SystemsEnergy ManagementPower ElectronicsBattery SystemsCharging SystemsDistributed Energy ResourcesEnergy StoragePower ManagementPower SystemsBattery Charge SchedulingBattery Energy Management SystemsBattery ManagementBattery-aware Power ManagementCharging ProcessesControl For RechargingElectrical Power InfrastructurePower Management Strategies
Data centers employ batteries for uninterruptible operation during maintenance and power failures, for example, when switching to diesel generator power after a utility power failure. Depleted batteries start to recharge once the input power is back, creating a sudden power spike in the power hierarchy. If not properly controlled, a sustained power overload can potentially trip circuit breakers, leading to service outages. Power overloads due to battery recharging are even more likely in oversubscribed data centers where the power infrastructure is aggressively provisioned for high utilization. The problem caused by simultaneous recharging of batteries in a data center has not been extensively studied and no real-world solutions have been proposed in the literature.In this paper, we identify the problem due to battery recharging with case studies from Facebook's data centers. We describe the solutions we have developed to coordinate charging of batteries without exceeding the circuit breaker power limit. We explain in detail, the variable battery charging algorithm built into the distributed battery charger hardware deployed in Facebook data centers, and the system design considerations necessary on a large scale. The new variable charger is able to reduce battery recharge power by up to 80%. We further leverage individual battery charging control mechanism to coordinate the charging process such that we charge the batteries according to priorities of applications running on the servers supported by the batteries. We evaluate our coordinated priority-aware battery charging algorithm by building a prototype in a Facebook production data center as well as through simulation experiments using production power traces. Our results show that we are able to meet reliability service level agreements by using our battery recharging algorithm, while satisfying given power constraints.
42
Power provisioning for a warehouse-sized computer
Xiaobo Fan, Wolf-Dietrich Weber, Luiz André Barroso · 2007 · 1.8K citations
Optimal power cost management using stored energy in data centers
Rahul Urgaonkar, Bhuvan Urgaonkar, Michael J. Neely et al. · 2011 · 441 citations
Charles Lefurgy, Xiaorui Wang, Malcolm Ware · 2007 · 289 citations
Ensemble-level Power Management for Dense Blade Servers
Parthasarathy Ranganathan, Phil Leech, David Irwin et al. · 2006 · 240 citations