Clinical & Experimental Allergy · 2020 · 17 citations · 17 references
Life SciencesImmunologyAllergyClinical ImmunologyHypersensitivityAllergen ImmunotherapyAllergen RecognitionAllergic ConditionsAllergic DiseaseAllergic RhinitisAllergy DiagnosticsAllergen-specific Immunoglobulin E AssaysAllergic Rhinitis EvaluationChemiluminescence DiagnosticsDiagnostic SensitivityGold Standard AssessmentImmunoassay InstrumentationMicroparticlesNasal Allergy Assessment
BACKGROUND: The measurement of specific IgE to allergenic extracts and molecules in patients with allergic rhinitis (AR) is crucial for a precise diagnosis and further immunotherapy. Companies providing in vitro diagnostic methods in allergology continuously strive for the optimization and modernization of such methods. A new generation of automated allergy tests based on chemiluminescence detection and paramagnetic microparticles is now available, with possible advantages in sample volume, cost-effectiveness and avoidance of sample-related interference. OBJECTIVES: To test whether sIgE antibody levels obtained with a new singleplex chemiluminescent method have a good agreement with the corresponding results obtained with a "gold standard" test. METHODS: Biomedical, Garden Grove, CA, USA). We evaluated the qualitative and quantitative performance of the new NOVEOS system in matching the outcome of ImmunoCAP to each of the examined allergens. RESULTS: In relation to ImmunoCAP, the overall diagnostic sensitivity and specificity of sIgE tests with NOVEOS were 90.8% (95% CI = 88.6-92.7) and 96.2% (95% CI = 93.9-97.8), respectively. These values were higher when only molecules were considered (sensitivity = 98.7% [95% CI = 96.4%-99.7%]; specificity = 94.2% [95% CI = 88.4%-97.6%]) and lower when only extracts were considered (sensitivity = 87.6% [95% CI = 84.7%-90.2%]; specificity = 97% [95% CI = 94.4%-98.6%]). Spearman's correlation between the data set of both methods for a ≥ 0.1 kU/L cut-off was 0.84 (p < .001). CONCLUSIONS: The new singleplex NOVEOS system presented good results for qualitative and quantitative comparisons when testing specific serum IgE antibodies against a range of 21 allergens. This novel immunoassay system using only 4 µl of sample per test appears to be robust and reliable and can, therefore, be used as an aid in allergy diagnosis.
17
EAACI Molecular Allergology User's Guide
Paolo Maria Matricardi, Jörg Kleine‐Tebbe, Hans Jürgen Hoffmann et al. · Pediatric Allergy and Immunology · 2016 · 911 citations · Full text
Life Sciences, Immunology, Allergy +16
G. K. Scadding, Harsha H. Kariyawasam, G. K. Scadding et al. · Clinical & Experimental Allergy · 2017 · 331 citations · Full text