PLoS neglected tropical diseases · 2020 · 39 citations · 37 references
Veterinary MedicineAnimal SciencesInfectious DiseasesDiagnostic MicrobiologyNecropsy PathologyOne Health Infectious DiseasesAnimal Infectious DiseasesVeterinary SurveillanceZoonotic Disease DetectionZoonotic Disease DiagnosisZoonotic Disease SurveillanceAnimal Disease SurveillanceAssayAssay SensitivityDiagnostic Accuracy StudiesDiagnostic Testing AccuracyDirect Fluorescent Antibody TestingNegative Control TestingSensitivity
Implementation of lateral flow devices (LFDs) for rabies antigen detection is expected to improve surveillance through the efficient detection of rabid animals in resource-limited settings; however, the use of LFDs for diagnosis remains controversial because some commercially available kits show low sensitivity. Therefore, we compared the diagnostic efficacy of three LFDs (ADTEC, Bionote, and Elabscience kits) paralleled with the direct fluorescent antibody test (dFAT) using fresh samples and investigated the diagnostic accuracies. To do so, we evaluated rabies-suspected samples submitted to the Regional Animal Disease Diagnostic Laboratory III, Philippines. Furthermore, we conducted real-time RT-PCR and sequencing to measure the accuracy of field laboratory diagnosis. The total number of animals submitted during this study period was 184 cases, including negative control samples. Of these, 53.9% (84 cases) were positive in the dFAT. Dogs were the most common rabies-suspected animal (n = 135). The sensitivities of the ADTEC and Bionote kits were 0.88 (74 cases) and 0.95 (80 cases), respectively. The specificity of both kits was 1.00 (100 cases). Furthermore, the sensitivity and specificity of the ADTEC kit after directly homogenizing the samples in assay buffer without dilution in phosphate-buffered saline (ADTEC kit DM) were 0.94 (79 cases) and 1.00 (100 cases), respectively. By contrast, there were no positive results using the Elabscience kit among all dFAT-positive samples. The sensitivity and specificity of LFDs make these tests highly feasible if properly used. Therefore, LFD tests can be used to strengthen the surveillance of rabies-infected animals in endemic and resource-limited settings.
37
MEGA X: Molecular Evolutionary Genetics Analysis across Computing Platforms
Sudhir Kumar, Glen Stecher, Michael Li et al. · Molecular Biology and Evolution · 2018 · 38.8K citations · Full text
Estimating the Global Burden of Endemic Canine Rabies
Katie Hampson, Laurent Coudeville, Tiziana Lembo et al. · PLoS neglected tropical diseases · 2015 · 1.8K citations · Full text
Laboratory Techniques in Rabies
Yvonne E. Cossart · Pathology · 1997 · 510 citations
Veterinary Medicine, Infectious Diseases, Veterinary Parasitology +6
Ryan M. Wallace, Eduardo A. Undurraga, Jesse D. Blanton et al. · Frontiers in Veterinary Science · 2017 · 197 citations · Full text
Veterinary Medicine, Preventive Medicine, Veterinary Public Health +17