CardioVascular and Interventional Radiology · 2020 · 16 citations · 17 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyDigital ImagingImage QualityImage Quality AssessmentMedical ImagingVascular ImagingClinical Image QualityContrast RatioContrast-to-noise Ratio EstimationImage Quality ScoringImage Quality TradeoffSignal-to-noise Ratio
Abstract Purpose The presence of metal implants may reduce angiographic image quality due to automated beam adjustments. Digital variance angiography (DVA) is reported to be superior to digital subtraction angiography (DSA) with increased contrast-to-noise ratio (CNR) and better image quality. The aim of the study was to evaluate whether DVA could counterbalance the image quality impairment of lower-limb angiographies with metal implants. Materials and Methods From November 2019 to January 2020, 85 raw lower-limb iodine contrast angiograms of 12 patients with metal implants were processed retrospectively with DVA analyses. For objective comparison, CNR of DSA and DVA images was calculated and the ratio CNR DVA /CNR DSA was determined. Visual image quality was evaluated in a paired comparison and by a five-grade Likert scale by three experienced radiologists. Results The CNR was calculated and compared in 1252 regions of interest in 37 image pairs containing metal implants. The median ratio of CNR DVA /CNR DSA was 1.84 with an interquartile range of 1.35–2.32. Paired comparison resulted in 84.5% in favour of DVA with an interrater agreement of 83.2% (Fleiss κ 0.454, p < 0.001). The overall image quality scores for DSA and DVA were 3.64 ± 0.08 and 4.43 ± 0.06, respectively ( p < 0.001, Wilcoxon signed-rank test) with consistently higher individual ratings for DVA. Conclusion Our small-sample pilot study shows that DVA provides significantly improved image quality in lower-limb angiography with metal implants, compared to DSA imaging. The improved CNR suggest that this approach could reduce radiation exposure for lower-limb angiography with metal implants. Level of Evidence Level 4, case studies
17
Interrater reliability: the kappa statistic
Marry L. McHugh · Biochemia Medica · 2012 · 18.6K citations · Full text
Interrater reliability: the kappa statistic.
Mary L. McHugh · PubMed · 2012 · 9.2K citations · Full text
ImageJ2: ImageJ for the next generation of scientific image data
Curtis Rueden, Johannes Schindelin, Mark Hiner et al. · BMC Bioinformatics · 2017 · 6.2K citations · Full text
Image Noise Reduction Algorithm for Digital Subtraction Angiography: Clinical Results
Michael Söderman, Staffan Holmin, Tommy Andersson et al. · Radiology · 2013 · 116 citations