Journal of Clinical Monitoring and Computing · 2020 · 14 citations · 22 references
MedicinePediatricsSurgeryAnesthesiaPediatric AnesthesiologyPediatric SurgeryIntraoperative MonitoringPediatric AnesthesiaPediatric Anesthetic TechniquesTemperature MeasurementTemperature SensorsBody Core TemperatureCore Body TemperatureEsophageal Temperature MonitoringObservational Study EvaluationPatient Temperature Monitoring
Abstract In pediatric anesthesia, deviations from normothermia can lead to many complications, with infants and young children at the highest risk. A measurement method for core temperature must be clinically accurate, precise and should be minimally invasive. Zero-heat-flux (ZHF) temperature measurements have been evaluated in several studies in adults. We assessed the agreement between the 3M Bair Hugger ™ temperature measurement sensor (T ZHF ) and esophageal temperature (T Eso ) in children up to and including 6 years undergoing surgery with general anesthesia. Data were recorded in 5 min-intervals. We investigated the accuracy of the ZHF sensor overall and in subgroups of different age, ASA classification, and temperature ranges by Bland–Altman comparisons of differences with multiple measurements. Change over time was assessed by a linear mixed model regression. Data were collected in 100 children with a median (1st–3rd quartile) age of 1.7 (1–3.9) years resulting in 1254 data pairs. Compared to T Eso (range from 35.3 to 39.3 °C; median 37.2 °C), T ZHF resulted in a mean bias of +0.26 °C (95% confidence interval +0.22 to +0.29 °C; 95% limits of agreement −0.11 to +0.62 °C). Lin’s concordance correlation coefficient was 0.89. There was no significant or relevant change of temperature over time (0.006 °C per hour measurement interval, p = 0.199) and no relevant differences in the subgroups. Due to the mean bias of +0.26 °C in T ZHF , the risk of hypothermia may be underestimated, while the risk of hyperthermia may be overestimated. Nevertheless, because of its high precision, we consider ZHF valuable for intraoperative temperature monitoring in children and infants.
22
Fitting Linear Mixed-Effects Models Using <b>lme4</b>
Douglas M. Bates, Martin Mächler, Benjamin M. Bolker et al. · Journal of Statistical Software · 2015 · 85.6K citations · Full text
Erik von Elm, Douglas G. Altman, Matthias Egger et al. · The Lancet · 2007 · 18.7K citations · Full text
Public Health, Public Health Practice, Epidemiologic Methods +10
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations