Evaluation of microhardness, sorption, solubility, and color stability of bulk fill resins: A comparative study

Luís Felipe Espíndola‐Castro, MA. Durão, T Pereira, AB. Cordeiro, GM. Monteiro

Journal of Clinical and Experimental Dentistry · 2020 · 21 citations · 25 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: Due to the increasing popularity of bulk fill resins, there is a concern that their components can be leached; this is because these are inserted in a single 4-5 mm increment. This in vitro study evaluated the microhardness, sorption, solubility, and color stability of three restorative bulk fill resins, namely: Filtek Bulk Fill (FBF), Tetric N-Ceram Bulk Fill (TNC), and Opus Bulk Fill (OBF). MATERIAL AND METHODS: Cylindrical samples were fabricated to be 15 mm in diameter and 1 mm thick (n = 10). For the microhardness test, three random indentations were formulated on the samples using a micro-durometer with a load of 300 gf for 15 s. Sorption and solubility were then evaluated (ISO 4049: 2009). Color stability was analyzed with a digital spectrophotometer three times (initially, after 24 h, and after 7 d) during immersion in coffee and distilled water (control). The Shapiro-Wilk test was applied to analyze normality. The Mann-Whitney and Kruskal-Wallis tests were used to compare the groups and the immersion solution, with a significance level of 5%. RESULTS: = 0.008). CONCLUSIONS: Bulk fill, color stability, composite resins, microhardness, solubility, sorption.

References

25