IEEE Electrical Insulation Magazine · 2020 · 13 citations · 8 references
EngineeringMarine EngineeringMarine Power SystemsOffshore EngineeringOffshore StructuresMarine TransformersOffshore MaterialsOffshore Oil And Gas FacilitiesMarine Transformer AnalysisMarine Transformer DiagnosticsMarine Transformer TestingOil AnalysisProject Evaluation CriteriaTractionTransformer InsulationTransformers In Marine Systems
It is generally recognized that dissolved gas analysis (DGA) is a powerful tool in the diagnosis of insulating liquid filled power equipment. There exist numerous evaluating schemes for the mineral oil filled equipment, nevertheless, the experiences show that a fine tuning and revision of the schemes is required for equipment filled with synthetic esters.
8