Biomechanics and Modeling in Mechanobiology · 2020 · 86 citations · 28 references
MedicineCardiologySurgeryComputational Fluid DynamicsDiagnostic ImagingFluid DynamicsAortic DiseaseAortic ImagingAortic SurgeryHemodynamicsHemodynamics Modeling4D Flow Magnetic Resonance ImagingArterial Fluid MechanicsBlood Flow DynamicsFluid Flow PatternsMagnetic Resonance Flow ImagingShear StressType B Aortic DissectionWall Shear Stress
In order for computational fluid dynamics to provide quantitative parameters to aid in the clinical assessment of type B aortic dissection, the results must accurately mimic the hemodynamic environment within the aorta. The choice of inlet velocity profile (IVP) therefore is crucial; however, idealised profiles are often adopted, and the effect of IVP on hemodynamics in a dissected aorta is unclear. This study examined two scenarios with respect to the influence of IVP-using (a) patient-specific data in the form of a three-directional (3D), through-plane (TP) or flat IVP; and (b) non-patient-specific flow waveform. The results obtained from nine simulations using patient-specific data showed that all forms of IVP were able to reproduce global flow patterns as observed with 4D flow magnetic resonance imaging. Differences in maximum velocity and time-averaged wall shear stress near the primary entry tear were up to 3% and 6%, respectively, while pressure differences across the true and false lumen differed by up to 6%. More notable variations were found in regions of low wall shear stress when the primary entry tear was close to the left subclavian artery. The results obtained with non-patient-specific waveforms were markedly different. Throughout the aorta, a 25% reduction in stroke volume resulted in up to 28% and 35% reduction in velocity and wall shear stress, respectively, while the shape of flow waveform had a profound influence on the predicted pressure. The results of this study suggest that 3D, TP and flat IVPs all yield reasonably similar velocity and time-averaged wall shear stress results, but TP IVPs should be used where possible for better prediction of pressure. In the absence of patient-specific velocity data, effort should be made to acquire patient's stroke volume and adjust the applied IVP accordingly.
28
Alicia M. Maceira, S. K. Prasad, Mohammad A. Khan et al. · European Heart Journal · 2006 · 554 citations
Factors Influencing Blood Flow Patterns in the Human Right Coronary Artery
Jerry G. Myers, J. A. Moore, M. Ojha et al. · Annals of Biomedical Engineering · 2001 · 240 citations
Kwong Ming Tse, Peixuan Chiu, Heow Pueh Lee et al. · Journal of Biomechanics · 2011 · 212 citations