Physics and Imaging in Radiation Oncology · 2020 · 16 citations · 30 references
MedicineRadiologyRadiation DetectionRadiation DosimetryRadiation MeasurementAbsorbed DoseDosimetry InstrumentationExternal Beam DosimetryFilm DosimetryQuality Assurance In DosimetryRadiation Dose MeasurementDose ResponseExternal Beam Radiotherapy DosimetryHigh-resolution DosimetryImaging-based DosimetryRadiation Dose EstimationSpatial Resolution In DosimetryTime ResolutionTwo-dimensional Dosimetry
Background and purposeThere is a continual need for more accurate and effective dosimetric systems for quality assurance (QA) as radiotherapy evolves in complexity. The purpose of this project was to introduce a new system that minimally perturbs the main beam, while assessing its real time 2D dose-rate and field shapes. The system combined reusability, linear dose-rate response, and high spatial and time resolution in a single radiation detection technology that can be applied to surface dose estimation and QA.Materials and methodsWe developed a 2D prototype system consisting of a camera, focusing lenses and short pass filter, placed on the head of a linear accelerator, facing an Al2O3:C,Mg radioluminescent film. To check the appropriateness of multi‐leaf collimator, stability/reproducibility QA tests were prepared using the treatment planning system: including the routinely used alternating leaves, chair and pyramid checks.ResultsThe Al2O3:C,Mg film did not perturb the dose vs. depth dose curves determined with a point detector (-0.5% difference). Our results showed a dose-rate linear film response (R2 = 0.999), from 5 to 600 MU/min. Measured output factors agreed with reference data within ~1%, indicating a potential for small field dosimetry. Both chair and pyramid measured profiles were comparable with those obtained with the treatment planning system within 1%. The alternating leaves test showed an average discrepancy in the valleys of 14%.ConclusionsThe prototype demonstrated promising results. It obviated the need for corrections regarding the relative position of the camera, confirming accurate dose-rate delivery and detection of radiation fields.
30
Fiji: an open-source platform for biological-image analysis
Johannes Schindelin, Ignacio Arganda‐Carreras, Erwin Frise et al. · Nature Methods · 2012 · 70.9K citations
A. Van Esch, Jörg Bohsung, Pekka Sorvari et al. · Radiotherapy and Oncology · 2002 · 177 citations
Eric C. Ford, Stephanie A. Terezakis, Annette Souranis et al. · International Journal of Radiation Oncology*Biology*Physics · 2012 · 170 citations