IEEE Journal of Solid-State Circuits · 2020 · 58 citations · 34 references
Natural SciencesElectrical EngineeringMaterials ScienceElectronic MaterialsMagnetic MaterialsSensorsDetector TechnologyMagnetic SensorsQuantum MeasurementSpintronicsControl Of Nitrogen-vacancy CentersDiamond Nitrogen-vacancy CentersDiamond Semiconductor DevicesIntegrated Magnetic SensorsMagnetic ResonanceMagnetic Resonance PhysicsMagnetometer InstrumentationSpin Excitation
Magnetometers based on quantum mechanical processes enable high sensitivity and long-term stability without the need for re-calibration, but their integration into fieldable devices remains challenging. This article presents a CMOS quantum vector-field magnetometer that miniaturizes the conventional quantum sensing platforms using nitrogen-vacancy (NV) centers in diamond. By integrating key components for spin control and readout, the chip performs magnetometry through optically detected magnetic resonance (ODMR) through a diamond slab attached to a custom CMOS chip. The ODMR control is highly uniform across the NV centers in the diamond, which is enabled by a CMOS-generated ~2.87 GHz magnetic field with <; 5% inhomogeneity across a large-area current-driven wire array. The magnetometer chip is 1.5 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> in size, prototyped in 65-nm bulk CMOS technology, and attached to a 300 × 80 μ m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> diamond slab. NV fluorescence is measured by CMOS-integrated photodetectors. This ON-chip measurement is enabled by efficient rejection of the green pump light from the red fluorescence through a CMOS-integrated spectral filter based on a combination of spectrally dependent plasmonic losses and diffractive filtering in the CMOS back-end-of-line (BEOL). This filter achieves a measured ~25 dB of green light rejection. We measure a sensitivity of 245 nT/Hz <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> , marking a 130 × improvement over a previous CMOS-NV sensor prototype, largely thanks to the better spectral filtering and homogeneous microwave generation over larger area.
34
Optical properties of metallic films for vertical-cavity optoelectronic devices
Aleksandar D. Rakić, Aleksandra B. Djurišić, J. Elazar et al. · Applied Optics · 1998 · 4.2K citations
Christian L. Degen, Friedemann Reinhard, Paola Cappellaro · Reviews of Modern Physics · 2017 · 3.9K citations · Full text
Natural Sciences, Physics, Photonics +13
Nanoscale imaging magnetometry with diamond spins under ambient conditions
Gopalakrishnan Balasubramanian, I. Y. Chan, Roman Kolesov et al. · Nature · 2008 · 2K citations · Full text
High-sensitivity diamond magnetometer with nanoscale resolution
Jacob M. Taylor, Paola Cappellaro, Lilian Childress et al. · Nature Physics · 2008 · 1.9K citations · Full text
Scanning Confocal Optical Microscopy and Magnetic Resonance on Single Defect Centers
Achim D. Gruber, A. Dräbenstedt, C. Tietz et al. · Science · 1997 · 1.8K citations
Natural Sciences, Materials Engineering, Materials Science +17