Infection Control and Hospital Epidemiology · 2020 · 29 citations · 20 references
Public HealthInfectious Disease ControlInfectious DiseasesInfection PreventionMedical MicrobiologyVentilationDecontamination ProceduresHigh-level DisinfectionMechanical VentilationRespiratory HygieneRespiratory Infection ControlRespiratory ProtectionAerosolized DisinfectionDecontaminationDisinfectionFiltration EfficiencyPeracetic Acid DecontaminationPeracetic Acid DisinfectantsRespirator DecontaminationRespiratory Decontamination
BACKGROUND: Critical shortages of personal protective equipment, especially N95 respirators, during the coronavirus disease 2019 (COVID-19) pandemic continues to be a source of concern. Novel methods of N95 filtering face-piece respirator decontamination that can be scaled-up for in-hospital use can help address this concern and keep healthcare workers (HCWs) safe. METHODS: A multidisciplinary pragmatic study was conducted to evaluate the use of an ultrasonic room high-level disinfection system (HLDS) that generates aerosolized peracetic acid (PAA) and hydrogen peroxide for decontamination of large numbers of N95 respirators. A cycle duration that consistently achieved disinfection of N95 respirators (defined as ≥6 log10 reductions in bacteriophage MS2 and Geobacillus stearothermophilus spores inoculated onto respirators) was identified. The treated masks were assessed for changes to their hydrophobicity, material structure, strap elasticity, and filtration efficiency. PAA and hydrogen peroxide off-gassing from treated masks were also assessed. RESULTS: The PAA room HLDS was effective for disinfection of bacteriophage MS2 and G. stearothermophilus spores on respirators in a 2,447 cubic-foot (69.6 cubic-meter) room with an aerosol deployment time of 16 minutes and a dwell time of 32 minutes. The total cycle time was 1 hour and 16 minutes. After 5 treatment cycles, no adverse effects were detected on filtration efficiency, structural integrity, or strap elasticity. There was no detectable off-gassing of PAA and hydrogen peroxide from the treated masks at 20 and 60 minutes after the disinfection cycle, respectively. CONCLUSION: The PAA room disinfection system provides a rapidly scalable solution for in-hospital decontamination of large numbers of N95 respirators during the COVID-19 pandemic.
20
Characteristics of Health Care Personnel with COVID-19 — United States, February 12–April 9, 2020
Sherry Burrer, Marie A. de Perio, Michelle M. Hughes et al. · MMWR Morbidity and Mortality Weekly Report · 2020 · 855 citations · Full text
Public Health, Infectious Disease Control, Infectious Diseases +16
Xu Wang, Xiaoxi Zhang, Jiangjiang He · BioScience Trends · 2020 · 186 citations · Full text
Planning, Emergency Preparedness, Infectious Disease Control +17