Multi-Laboratory Evaluation of a Lateral Flow Rapid Test for Detection of Amebic Liver Abscess

Rahmah Noordin, Muhammad Hafiznur Yunus, Syazwan Saidin, Zeehaida Mohamed, Isabel Fuentes Corripio, José Miguel Rubio, Majid Golkar, Shamilah Hisam, Rogan Lee, Rohela Mahmud

American Journal of Tropical Medicine and Hygiene · 2020 · 18 citations · 25 references

DOIFull text

Open access

Concepts

Abstract

= 151). The diagnostic sensitivity was tested with a total of 154 samples, and the results were variable. It was high in three laboratories (89-94%), and moderate (72%) and low (38%) in two other laboratories. Challenges and issues faced in the evaluation process are discussed. Nevertheless, XEh Rapid is promising to be developed into a point-of-care test in particular for resource-limited settings, and thus merits further confirmation of its diagnostic sensitivity.

References