Performance Investigation of Consequent-Pole PM Machines With E-core and C-core Modular Stators

Rui Zhou, Guangjin Li, K. Zhang, Z. Q. Zhu, Martin P. Foster, David A. Stone

IEEE Transactions on Energy Conversion · 2020 · 27 citations · 21 references

Concepts

Abstract

This article investigates some novel modular consequent pole PM machines (CPMs) with E-core and C-core stators. Different slot-pole number combinations including 12-slot/10-pole ( <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Ns&gt;2p</i> ) and 12-slot/14-pole ( <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Ns&lt;2p</i> ) have been investigated. Their static and dynamic electromagnetic performances have been investigated, e.g. the phase back-EMF, on-load torque, torque-speed curves, power factor-speed curves and also efficiency maps are compared. It is found that the existence of flux gaps (FGs) can improve the average torque of the 12-slot/14-pole E-core modular CPMs while the C-core structure can be a better candidate where relatively low torque ripple is desirable. Moreover, by selecting proper FG width, the 12-slot/14-pole E-core modular CPMs can achieve better flux-weakening capability and higher efficiency while the 12-slot/10-pole C-core modular CPMs can have higher power factors over the whole speed range. The finite element simulation results have been validated by a series of experiments using 12-slot/14-pole modular CPMs with both C-core and E-core stators.

References

21