Magnetic Resonance in Medicine · 2020 · 27 citations · 30 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyImage Quality AssessmentMagnetic Resonance ImagingRepeatability
PURPOSE: To investigate the repeatability and reproducibility of radiomic features extracted from MR images and provide a workflow to identify robust features. METHODS: -weighted images of a pelvic phantom were acquired on three scanners of two manufacturers and two magnetic field strengths. The repeatability and reproducibility of features were assessed by the intraclass correlation coefficient and the concordance correlation coefficient, respectively, and by the within-subject coefficient of variation, considering repeated acquisitions with and without phantom repositioning, and with different scanner and acquisition parameters. The features showing intraclass correlation coefficient or concordance correlation coefficient >0.9 were selected, and their dependence on shape information (Spearman's ρ > 0.8) analyzed. They were classified for their ability to distinguish textures, after shuffling voxel intensities of images. RESULTS: From 944 two-dimensional features, 79.9% to 96.4% showed excellent repeatability in fixed position across all scanners. A much lower range (11.2% to 85.4%) was obtained after phantom repositioning. Three-dimensional extraction did not improve repeatability performance. Excellent reproducibility between scanners was observed in 4.6% to 15.6% of the features, at fixed imaging parameters. In addition, 82.4% to 94.9% of the features showed excellent agreement when extracted from images acquired with echo times 5 ms apart, but decreased with increasing echo-time intervals, and 90.7% of the features exhibited excellent reproducibility for changes in pulse repetition time. Of nonshape features, 2.0% was identified as providing only shape information. CONCLUSION: We showed that radiomic features are affected by MRI protocols and propose a general workflow to identify repeatable, reproducible, and informative radiomic features to ensure robustness of clinical studies.
30
3D Slicer as an image computing platform for the Quantitative Imaging Network
Andriy Fedorov, Reinhard Beichel, Jayashree Kalpathy–Cramer et al. · Magnetic Resonance Imaging · 2012 · 8.9K citations · Full text
Arts, Computer Science, Radiology +12
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
Radiomics: Images Are More than Pictures, They Are Data
Robert J. Gillies, Paul E. Kinahan, Hedvig Hricak · Radiology · 2015 · 8.3K citations
Computational Radiomics System to Decode the Radiographic Phenotype
Joost J. M. van Griethuysen, Andriy Fedorov, Chintan Parmar et al. · Cancer Research · 2017 · 6.5K citations · Full text