Frontiers in Neuroscience · 2020 · 10 citations · 20 references
NursingCardiologyPhysiologyClinical CardiologyPhysiological Systems ModelingPsychophysiologyBlood Pressure Signal AnalysisCardiac PhysiologyCardiovascular MonitoringHeart Rate VariabilityHemodynamicsBeat-to-beat Blood Pressure AnalysisBlood PressureBlood Pressure VariabilityCausal RelationshipsHeart RateR-r Interval VariabilitySlow BreathingSystolic Blood Pressure
To quantify spontaneous baroreflex sensitivity (BRS), many groups use the xBRS method, which calculates the cross-correlation between the systolic beat-to-beat blood pressure and the R-R interval, resampled at 1 Hz, in a 10 s sliding window, with 0-5 s delays for the interval. The delay with the greatest positive correlation is selected and, if significant, the quotient of the standard deviations of R-R intervals and systolic blood pressures are recorded as corresponding xBRS value. In this paper we test the hypothesis that the xBRS method quantifies the causal interactions of spontaneous BRS at rest and is not exclusively dominated by the quotient of heart rate and systolic blood pressure variability (HRV/BPV). Therefore, we retrospectively analyzed 1828 beat-to-beat time series and the corresponding systolic blood pressure at rest. We found a high correlation between the HRV/BPV quotient and the xBRS of r=0.94 (p<0.001). Two different surrogate analyses showed that the xBRS method is not able to quantify causal relationships between the two signals; it cannot distinguish between random and baroreflex controlled sequences but rather determines the HRV/BPV quotient. We conclude that the xBRS method has a potentially large bias in characterizing the capacity of the arterial baroreflex under resting conditions. During slow breathing, estimates for xBRS are significantly increased, which clearly shows that measurements at rest only involve limited baroreflex activity but does neither challenge nor show the full capacity of the arterial baroreflex. We show that xBRS is exclusively dominated by the heart rate to systolic blood pressure ratio (r=0.965, p<0.001). Further investigations will show whether certain autonomous testing procedures such as slow breathing or orthostatic testing can serve as a basis for a non-invasive evaluation of baroreflex sensitivity.
20
Improved Surrogate Data for Nonlinearity Tests
Thomas Schreiber, Andreas Schmitz · Physical Review Letters · 1996 · 1.5K citations · Full text
Computing, Biostatistics, Statistics +13
A new approach to analysis of the arterial baroreflex.
Giovanni Bertinieri, Marco Di Rienzo, Anita Cavallazzi et al. · PubMed · 1985 · 472 citations
Medicine, Cardiology, Pharmacology +17
Time-domain cross-correlation baroreflex sensitivity
Berend E. Westerhof, Janneke Gisolf, Wim J. Stok et al. · Journal of Hypertension · 2004 · 253 citations
Engineering, Cardiology, Physiology +17