Publication | Closed Access
Transfusion of blood components containing <scp>ABO</scp>‐incompatible plasma does not lead to higher mortality in civilian trauma patients
19
Citations
18
References
2020
Year
The transfusion of incompatible plasma in civilian trauma resuscitation does not lead to higher 30-day mortality. The finding of higher mortality in a select group of recipients in the secondary analysis warrants further study.