Lasers in Surgery and Medicine · 2020 · 12 citations · 23 references
MedicineUrologyFemale UrologyUrodynamicsVoiding DysfunctionBladder Function AssessmentContinence AssessmentIncontinence ManagementLaser SurgeryUrinary IncontinenceUrinary Incontinence AssessmentIncontinence Severity MeasurementLasersStress Urinary Incontinence EvaluationTreatment ParametersTreatment Tolerance MonitoringValidated Symptom Questionnaires
Background and Objectives Energy‐based treatments have been found to be a promising treatment modality for improving stress urinary incontinence (SUI) symptoms. This prospective two‐center study was designed to evaluate the efficacy of fractional‐pixel CO 2 laser for the treatment of SUI. Study Design/Materials and Methods Eighty‐five women with SUI symptoms as per the cough stress test and validated International Consultation on Incontinence Questionnaire—Urinary Incontinence Short Form (ICIQ‐UI‐SF), were treated intravaginally with Pixel‐CO 2 laser. Two treatment sessions were performed with a 1‐month interval. Safety and treatment tolerance were assessed by the visual analog scale (VAS) immediately and at 1 week after each laser treatment. Associations of age and body mass index (BMI) with the ICIQ‐UI‐SF score were statistically assessed by the Jonckheere–Terpstra test. Results The ICIQ‐UI‐SF score was 12.0 at baseline, 7.0, after the first treatment, and 3.5 after the second treatment ( P = 0.001). For women with BMI (25.0–29.9), the ICIQ‐UI‐SF score was 9.0 at the baseline, 6.0 after 1 month, and 5.0 at the 6 months follow‐up visit ( P = 0.04). For women with BMI ≥ 30.0, the ICIQ‐UI‐SF score was reduced from 14.0 to 8.0 1 month after the baseline and 5.0 at the 6‐month follow‐up visit ( P = 0.001). SUI severity evaluation at baseline showed that 27.1% of women had mild, 24.7% had moderate, 45.9% had severe, and 2.4% had very severe SUI symptoms. SUI severity scores were significantly reduced, with 45.8% of women with no SUI symptoms, 18.8% with mild, 20.8% with moderate, and 14.6% with severe SUI symptoms at the 6‐month follow‐up. The patient's evaluation of VAS after the first treatment was 1.0–1.5 (0–10) and 0.0 1 week after the second treatment. Conclusion Fractional‐pixel CO 2 laser is safe and effective for treating SUI. No adverse event or significant pain was reported during or after the procedure. Its safety and efficacy are clearly demonstrated. Lasers Surg. Med. © 2020 Wiley Periodicals LLC
23
Mija Blaganje, Darija Šćepanović, Lidija Žgur et al. · European Journal of Obstetrics & Gynecology and Reproductive Biology · 2018 · 127 citations · Full text
Pablo González Isaza, Kinga Jaguszewska, José Luis Santonja Cardona et al. · International Urogynecology Journal · 2017 · 116 citations · Full text
Medicine, Urology, Female Urology +13