Practical challenges to the clinical implementation of saliva for SARS-CoV-2 detection

Nancy Matic, Aleksandra Stefanovic, Victor C. M. Leung, Tanya Lawson, Gordon Ritchie, Lynne Li, Sylvie Champagne, Marc G. Romney, Christopher F. Lowe

medRxiv · 2020 · 10 citations · 20 references

DOIFull text

Open access

Concepts

Abstract

Abstract Due to global shortages of flocked nasopharyngeal swabs and appropriate viral transport media during the COVID-19 pandemic, alternate diagnostic specimens for SARS-CoV-2 detection are sought. The accuracy and feasibility of saliva samples collected and transported without specialized collection devices or media were evaluated. Saliva demonstrated good concordance with paired nasopharyngeal swabs for SARS-CoV-2 detection in 67/74 cases (90.5%), though barriers to saliva collection were observed in long-term care residents and outbreak settings. SARS-CoV-2 RNA was stable in human saliva at room temperature for up to 48 hours after initial specimen collection, informing appropriate transport time and conditions.

References

20