Malaria Journal · 2020 · 23 citations · 40 references
MedicineInfectious DiseasesMolecular BiologyDiagnostic MicrobiologyEarly DetectionMolecular DiagnosticsAssay ValidationInfectious Disease Molecular TestingMalariaMolecular DiagnosisMolecular SurveillancePathogen DetectionComparative EvaluationDisease Surveillance ReportingMalaria EliminationMalaria SurveillanceMolecular Parasite DetectionMolecular Pathogen DetectionReal-time Polymerase Chain Reaction (Pcr)Surveillance Data Reporting
BACKGROUND: The monkey parasite Plasmodium knowlesi is an emerging public health issue in Southeast Asia. In Sabah, Malaysia, P. knowlesi is now the dominant cause of human malaria. Molecular detection methods for P. knowlesi are essential for accurate diagnosis and in monitoring progress towards malaria elimination of other Plasmodium species. However, recent commercially available PCR malaria kits have unpublished P. knowlesi gene targets or have not been evaluated against clinical samples. METHODS: Two real-time PCR methods currently used in Sabah for confirmatory malaria diagnosis and surveillance reporting were evaluated: the QuantiFast™ Multiplex PCR kit (Qiagen, Germany) targeting the P. knowlesi 18S SSU rRNA; and the abTES™ Malaria 5 qPCR II kit (AITbiotech, Singapore), with an undisclosed P. knowlesi gene target. Diagnostic accuracy was evaluated using 52 P. knowlesi, 25 Plasmodium vivax, 21 Plasmodium falciparum, and 10 Plasmodium malariae clinical isolates, and 26 malaria negative controls, and compared against a validated reference nested PCR assay. The limit of detection (LOD) for each PCR method and Plasmodium species was also evaluated. RESULTS: The sensitivity of the QuantiFast™ and abTES™ assays for detecting P. knowlesi was comparable at 98.1% (95% CI 89.7-100) and 100% (95% CI 93.2-100), respectively. Specificity of the QuantiFast™ and abTES™ for P. knowlesi was high at 98.8% (95% CI 93.4-100) for both assays. The QuantiFast™ assay demonstrated falsely-positive mixed Plasmodium species at low parasitaemias in both the primary and LOD analysis. Diagnostic accuracy of both PCR kits for detecting P. vivax, P. falciparum, and P. malariae was comparable to P. knowlesi. The abTES™ assay demonstrated a lower LOD for P. knowlesi of ≤ 0.125 parasites/µL compared to QuantiFast™ with a LOD of 20 parasites/µL. Hospital microscopy demonstrated a sensitivity of 78.8% (95% CI 65.3-88.9) and specificity of 80.4% (95% CI 67.6-89.8) compared to reference PCR for detecting P. knowlesi. CONCLUSION: The QuantiFast™ and abTES™ commercial PCR kits performed well for the accurate detection of P. knowlesi infections. Although the QuantiFast™ kit is cheaper, the abTES™ kit demonstrated a lower LOD, supporting its use as a second-line referral-laboratory diagnostic tool in Sabah, Malaysia.
40
A large focus of naturally acquired Plasmodium knowlesi infections in human beings
Balbir Singh, Lee Kim Sung, Asmad Matusop et al. · The Lancet · 2004 · 1.2K citations
Mathieu Rougemont, M. van Saanen, Roland Sahli et al. · Journal of Clinical Microbiology · 2004 · 468 citations · Full text
Veterinary Medicine, Infectious Diseases, Molecular Biology +17
First case of a naturally acquired human infection with Plasmodium cynomolgi
Shamilah Hisam, Marta Lanza, Adela Ida Jiram et al. · Malaria Journal · 2014 · 328 citations · Full text
Bridget E. Barber, Timothy William, Matthew J. Grigg et al. · Clinical Infectious Diseases · 2012 · 270 citations · Full text