International Journal of Applied Electromagnetics and Mechanics · 2020 · 26 citations · 24 references
EngineeringMaterials EngineeringMechanical EngineeringAcousticsMetallurgyUltrasoundAcoustic Wave PropagationTransducer TechnologyUltrasonicsUltrasound InstrumentationUltrasound PhysicsVibration MeasurementForgingHigh-temperature TestingNon-destructive TestingPulse CompressionSurface CoolingUltrasonic Thickness MeasurementUltrasonic TransducersUltrasonic Waves
The interest in applying non-destructive testing to the examination of the flaw and measurement of the thickness in the metals at high temperatures is increasing as the metal processing becomes continuous. Based on this background, we designed a water-cooled shear wave Electromagnetic Acoustic Transducer (EMAT) with a surface cooling technique, and the conversion efficiency could be improved by surface cooling. We used the chirp pulse compression technique to process the raw ultrasonic wave signal without synchronous average. Besides, a large casting slab with coarse grains and a massive forging with high temperatures were chosen as the testing objects. Then, the effect of the lift-off distance on the Signal-to-Noise Ratio (SNR) of ultrasonic signals from the EMATs operated in both the pulse-echo mode and pitch-catch mode was investigated. Subsequently, the ultrasonic signals were de-noised respectively by synchronous averages and pulse compression, and the noise reduction ability was compared. Finally, the EMAT was tested with the forging at different temperatures from 92 °C to 730 °C. The performance of the EMAT with the excitation of a tone-burst signal was also compared with the performance of the EMAT using pulse compression technique. Results show that the lift-off, SNR, range resolution, and inspection efficiency can be largely enhanced with the signal processing of chirp pulse compression to the ultrasonic wave signal with no synchronous averaging. When the forging’s temperature is 730 °C, the SNR of the compressed signal is comparable to the SNR of the signal processed with 64 synchronous averages, and the wave-packet duration can be reduced by 80.5%. The proposed EMAT detection technique is particularly suited for real-time measurement and high-temperature testing.
24
Optimal design of EMAT transmitters
Koorosh Mirkhani, Chris Chaggares, Chris Masterson et al. · NDT & E International · 2003 · 111 citations
Study on the lift-off effect of EMAT
Songling Huang, Wei Zhao, Yongsheng Zhang et al. · Sensors and Actuators A Physical · 2009 · 88 citations
Engineering, Aerospace Engineering, Electrical Engineering +5