Stroke · 1999 · 101 citations · 30 references
MedicineCardiologyRadiologyDiagnostic ImagingUltrasonographyUltrasoundCardiac Shunt EvaluationContrast AgentsContrast MediaDoppler UltrasonographyDoppler UltrasoundTransesophageal EchocardiographyAssessment Of Cardiac ShuntsContrastIntracardiac Shunt AssessmentIntracardiac Shunt DetectionMiddle Cerebral Artery Doppler VelocimetryRight-to-left Shunt AssessmentRight-to-left Shunt DetectionTranscranial Ultrasound Imaging
BACKGROUND AND PURPOSE: Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Furthermore, we assessed the side distribution of thus provoked artificial cardiac emboli. METHODS: Fifty-four patients were investigated by TEE and by bilateral TCD of the middle cerebral artery. The following protocol was performed twice: injection of 9 mL of agitated saline without Valsalva maneuver, injection of 9 mL of agitated saline with Valsalva maneuver, injection of 5 mL of a commercial galactose-based contrast agent without Valsalva maneuver, and injection of 5 mL of the galactose-based contrast agent with Valsalva maneuver. RESULTS: In 18 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt positive). Twenty-nine patients were negative in both investigations, 1 was positive on TEE and negative on TCD, and 6 patients were only positive on TCD. Both bilateral and repeated recordings increased the sensitivity of contrast TCD. There was a symmetrical distribution of microembolic signals in the right and left middle cerebral artery. CONCLUSIONS: TCD performed twice and with the use of saline or a galactose-based contrast agent is a sensitive method in the identification of cardiac right-to-left shunts also identified by TEE. The cardiac microemboli in this study did not show any side preference for one of the middle cerebral arteries.
30
Consensus on Microembolus Detection by TCD
E. Bernd Ringelstein, Dirk W. Droste, Viken L. Babikian et al. · Stroke · 1998 · 634 citations · Full text
Patent Foramen Ovale as a Risk Factor for Cryptogenic Stroke
Marco Di Tullio, Ralph L. Sacco, Aasha S. Gopal et al. · Annals of Internal Medicine · 1992 · 601 citations
Anthony C. Pearson, Arthur J. Labovitz, Satyararayan Tatineni et al. · Journal of the American College of Cardiology · 1991 · 569 citations
Medicine, Cardiology, Radiology +17