Reproductive Biology and Endocrinology · 2020 · 27 citations · 19 references
PharmacyPharmaceuticsGood Laboratory PracticeImmunotechnologyReproductive MedicineBioanalytical Method ValidationImmunoassay AnalysisImmunoassay DevelopmentAnti-müllerian Hormone AssessmentAnti-müllerian Hormone TestingHormone ImmunoassaysImmunoassay CalibrationImmunoassay MethodologyImmunoassay ValidationImmunoassaysLong-term Stability
BACKGROUND: There is a need for a reference material to support the development and ensure the quality of immunoassays for human AMH. A batch of ampoules, coded 16/190, containing lyophilised recombinant AMH was evaluated in a WHO Collaborative Study. The aims of the study were to determine the AMH content in terms of the calibration of each immunoassay method, to predict long-term stability and to assess the suitability of the preparation to calibrate AMH immunoassays. METHODS: Study participants were asked to report the AMH content of specific dilutions of coded ampoules of 16/190 and a comparator preparation containing approximately half the AMH content. In each assay, participants also reported the AMH content of 22 patient samples to assess commutability. A robust all-laboratory geometric mean of the content estimates was determined using the laboratory geometric mean estimates. Commutability was assessed using a difference in bias approach. Stability was predicted by the measurement of thermally accelerated degradation samples. RESULTS: Seven laboratories performed twenty-one immunoassay method-platform combinations, sixteen of which provided data which met the validity criteria, giving a consensus geometric mean estimate of AMH content of 511 ng/ampoule (95% CI, 426-612, n = 16, GCV 42%) and a robust geometric mean of 489 ng/ampoule. By contrast, the GCV% for the all-laboratory geometric mean of the relative content estimates for the comparator sample to 16/190 was 12%. Commutability was assessed using 20 of the 22 representative patient samples. Of the valid assays, 16/190 was within the limits of acceptable commutability for 6 methods, partially commutable for a further 3 methods and non-commutable when measured by 7 methods. The preparation was predicted to be highly stable when stored at - 20 °C. CONCLUSION: The majority of methods met the validity criteria. Content estimates showed a high between-method variability, yet assays exhibited a similar proportionality of response as demonstrated using the comparator sample. 16/190 was commutable in some but not all methods. On the basis of these results, it was agreed by the WHO Expert Committee on Biological Standardization to establish 16/190 as a WHO Reference Reagent for AMH with a content defined by consensus immunoassay of 489 ng/ampoule.
19
Sioḃán D. Harlow, Margery Gass, Janet E. Hall et al. · The Journal of Clinical Endocrinology & Metabolism · 2012 · 1.3K citations · Full text
Medicine, Endocrinology, Gynecology +17
The physiology and clinical utility of anti-Müllerian hormone in women
Didier Dewailly, Claus Yding Andersen, Adam Balen et al. · Human Reproduction Update · 2014 · 1.1K citations · Full text
Medicine, Endocrinology, Physiology +14
Anders Nyboe Andersen, Scott M. Nelson, Bart C.J.M. Fauser et al. · Fertility and Sterility · 2016 · 286 citations · Full text