JTCVS Techniques · 2020 · 15 citations · 28 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyVascular SurgeryAortic SurgeryAortic Valve DiseaseCardiac Valve SurgeryMitral Valve DiseaseSurgical Valve ReplacementAortic Annulus DilationAortic Root AssessmentAortic Root DilationAortic Root DiseaseLeakageProsthesis-patient MismatchRoot EnlargementSurvival Probability
OBJECTIVES: To determine the influence of surgical techniques adopted to avoid suture line disruption, periprosthetic leakage, patch dislodgement, pericardial patch aneurysm formation, and the long-term stability of aortic root enlargement (ARE) during aortic valve replacement (AVR). METHODS: One hundred fifteen patients undergoing AVR or combined aortic and mitral valve replacements with Nicks' posterior ARE between 1997 and 2019 underwent long-term echocardiographic and angio-computed tomographic evaluation. Age was 11-72 years (AVR: median, 30; interquartile range, 21-47 years; AVR and mitral valve replacement: median, 27.5; interquartile range, 20-37.5 years). The aortotomy was closed using autologous pericardial patch and Teflon-buttressed sutures. RESULTS: Hospital mortality was 1.7% (n = 2), with 4 (3.5%) late deaths. At a mean follow-up of 123.11 ± 77.67 months, the survival probability from Kaplan-Meier was 93.25 ± 0.03%. No cases of severe prosthesis-patient mismatch (PPM) were observed, and only 2 patients had moderate PPM. Median aortic root diameters at the level of sinus of Valsalva and sinotubular junction were 32 (29-35) mm and 33 (30-36) mm, respectively, at discharge, and were 33 (30-36) mm, and 33 (31-37) mm, respectively, at latest follow-up, with no cases of late pericardial patch aneurysm. CONCLUSIONS: ARE is a safe adjunct to AVR in patients with a small aortic annulus to prevent PPM. Retention of a pericardial collar and Teflon-buttressed sutures is an expedient, safe, and effective technique in reducing bleeding at the enlarged ventriculo-aortic junction. Autologous pericardial patch aortoplasty is not associated with late aneurysm/pseudoaneurysm formation.
28
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Danny Dvir, John G. Webb, Sabine Bleiziffer et al. · JAMA · 2014 · 906 citations · Full text
Medicine, Cardiology, Surgery +17
Impact of Valve Prosthesis-Patient Mismatch on Short-Term Mortality After Aortic Valve Replacement
Claudia Blais, Jean G. Dumesnil, Richard Baillot et al. · Circulation · 2003 · 557 citations
Medicine, Cardiology, Surgery +16
Hypoplasia of the aortic root : The problem of aortic valve replacement
Rowan Nicks, T. B. Cartmill, L. Bernstein · Thorax · 1970 · 341 citations · Full text