BACKGROUND AND AIMS: Rising effects of temperature due to laser use during root canal disinfection may harm periodontium and alveolar bone. Therefore, the aim of this study was to estimate the surface root temperature of lower incisors throughout the application of different power levels and times of an 810-nm diode laser. MATERIALS AND METHODS: = 10). Then, the peak temperatures at the middle and apical regions of the root surface were registered using a thermocouple. RESULTS: Temperature rise of root surface at all the selected output powers was below 7°C. The highest temperature value was obtained in the apical region at 60s when the root canal irradiated at 1.95 W output power. CONCLUSION: Diode laser is safe for use as a root canal disinfectant. Time of exposure to laser irradiation has an effect on the temperature difference at different output powers.