Magnetic Resonance in Medicine · 2020 · 32 citations · 37 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyHepatobiliary ImagingLiver ImagingMagnetic Resonance Contrast MechanismsMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingProton Density ContrastPulse Sequence DesignSaturationSaturation ProcessingUltrasonography Of The LiverVariable Flip Angle Sequences
Purpose To describe and validate a simultaneous proton density fat‐fraction (PDFF) imaging and water‐specific T 1 mapping (T 1(Water) ) approach for the liver (PROFIT 1 ) with mapping and low sensitivity to calibration or inhomogeneity. Methods A multiecho gradient‐echo sequence, with and without saturation preparation, was designed for simultaneous imaging of liver PDFF, , and T 1(Water) (three slices in ~13 seconds). Chemical‐shift‐encoded MRI processing yielded fat‐water separated images and maps. T 1(Water) calculation utilized saturation and nonsaturation‐recovery water‐separated images. Several variable flip angle schemes across k‐space (increasing flip angles in sequential RF pulses) were evaluated for minimization of T 1 weighting, to reduce the dependence of T 1(Water) and PDFF (reduced flip angle dependence). T 1(Water) accuracy was validated in mixed fat‐water phantoms, with various PDFF and T 1 values (3T). In vivo application was illustrated in five volunteers and five patients with nonalcoholic fatty liver disease (PDFF, T 1(Water) , ). Results A sin 3 (θ) flip angle pattern (0 < θ < π/2 over k‐space) yielded the largest PROFIT 1 signal yield with negligible dependence for both T 1(Water) and PDFF. Mixed fat‐water phantom experiments illustrated excellent agreement between PROFIT 1 and gold‐standard spectroscopic evaluation of PDFF and T 1(Water) (<1% T 1 error). In vivo PDFF, T 1(Water) , and maps illustrated independence of the PROFIT 1 values from inhomogeneity and significant differences between volunteers and patients with nonalcoholic fatty liver disease for T 1(Water) (927 ± 56 ms vs. 1033 ± 23 ms; P < .05) and PDFF (2.0% ± 0.8% vs. 13.4% ± 5.0%, P < .05). was similar between groups. Conclusion The PROFIT 1 pulse sequence provides fast simultaneous quantification of PDFF, T 1(Water) , and with minimal sensitivity to miscalibration or inhomogeneity.
37
Stefan K. Piechnik, Vanessa M. Ferreira, Erica Dall’Armellina et al. · Journal of Cardiovascular Magnetic Resonance · 2010 · 664 citations · Full text
Medicine, Bioengineering, Cardiology +17