IEEE Transactions on Dielectrics and Electrical Insulation · 2020 · 17 citations · 11 references
Natural SciencesElectrical EngineeringPhysicsAtmospheric ElectricityElectromagneticsElectromagnetismElectrical ConductivityLightning CurrentLightning PhysicsThunderstorm ElectricityThunderstorm ElectrificationBreakdown CharacteristicsBreakdown In Electrified CloudsBreakdown VoltageElectric Field Thresholds For BreakdownElectrical Breakdown In AirElectrical Breakdown Strength
This paper provides a comparative study on the impulse breakdown performance of SF <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> and 20% C <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf> F <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">7</inf> CN / 80% CO <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> gas mixture under weak non-uniform electric fields. Two geometrically distinct electrode configurations, with similar field utilization factor, were subjected to standard lightning impulse waveform (1.2/50 μs) and the effects of pressure, gap distance and impulse polarity on breakdown characteristics were studied. The results show that SF <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> has a higher breakdown voltage than the C <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</inf> F <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">7</inf> CN/CO <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> mixture and the positive 1.2/50 μs breakdown voltages were found to be higher than the negative counterparts. These results show that the effect of polarity on breakdown voltage does not exclusively depend on electrode geometry but also on pressure and gas type. The results of this paper identify the weaker polarity for 20% C3F7CN / 80% CO2 tested with hemispherical rod-plane and coaxial electrode configurations and the results contribute to the design of SF <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf> -free gas insulated equipment.
11
Green Gas to Replace SF6 in Electrical Grids
Yannick Kieffel, Todd A. Irwin, P. Ponchon et al. · IEEE Power and Energy Magazine · 2016 · 349 citations
Houssem Eddine Nechmi, Abderrahmane Béroual, A. Girodet et al. · IEEE Transactions on Dielectrics and Electrical Insulation · 2016 · 219 citations
Natural Sciences, Electrical Engineering, Materials Science +16
Abderrahmane Béroual, A. Haddad · Energies · 2017 · 209 citations · Full text
Engineering, Electrical Engineering, Environmental Engineering +14