Aerospace · 2020 · 80 citations · 29 references
EngineeringAerospace EngineeringPhysicsPlasma PhysicsPropulsionSpacecraft DesignAccelerator PhysicsElectric PropulsionIon PropulsionPlasma PropulsionPropulsion System PerformanceSpace PlasmasAccelerator Grid DesignElectrospray PropulsionElectrospray ThrustersGrid SpacingLifetime ModelingMass FluxThruster DesignThruster Lifetime
Ionic liquid electrospray thrusters can produce microNewton precision thrust at a high thrust–power ratio but have yet to demonstrate lifetimes suitable for most missions, with propellant accumulation on extractor and accelerator grids being the most significant life‑limiting mechanism. The study aims to develop a life model to examine how design features, operating conditions, and emission properties affect porous accelerator grid saturation time in droplet emission mode. The authors constructed a life model that incorporates design parameters, operating conditions, and emission characteristics to predict grid saturation time. The model shows that 3–7 % increases in grid aperture radius or spacing can boost lifetime by 200–400 %, while misalignment can cut lifetime by 20–50 %; larger aperture radii raise backstreaming current, but applying a kV‑scale accelerator grid potential suppresses backstreaming to negligible levels across geometries.
Ionic liquid electrospray thrusters are capable of producing microNewton precision thrust at a high thrust–power ratio but have yet to demonstrate lifetimes that are suitable for most missions. Accumulation of propellant on the extractor and accelerator grids is thought to be the most significant life-limiting mechanism. In this study, we developed a life model to examine the effects of design features, operating conditions, and emission properties on the porous accelerator grid saturation time of a thruster operating in droplet emission mode. Characterizing a range of geometries and operating conditions revealed that modifying grid aperture radius and grid spacing by 3–7% can significantly improve thruster lifetime by 200–400%, though a need for explicit mass flux measurement was highlighted. Tolerance analysis showed that misalignment can result in 20–50% lifetime reduction. In addition, examining the impact of electron backstreaming showed that increasing aperture radius produces a significant increase in backstreaming current compared to changing grid spacing. A study of accelerator grid bias voltages revealed that applying a reasonably strong accelerator grid potential (in the order of a kV) can minimize backstreaming current to negligible levels for a range of geometries.
29
The Fluid Dynamics of Taylor Cones
Juan Fernández de la Mora · Annual Review of Fluid Mechanics · 2006 · 587 citations
Engineering, Physics, Fluid Dynamics +13