Medical Physics · 2020 · 29 citations · 23 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic Nuclear MedicineDiagnostic RadiologyChest RadiographyChest RadiologyNuclear Medicine ImagingPulmonary Function AssessmentPulmonary ImagingRadiographic ImagingComparative Diagnostic PerformanceFunctional ImagingLung Density MeasurementLung Density QuantificationLung Perfusion ImagingLung Perfusion ScansPulmonary Functional ImagingPulmonary Ventilation Imaging
Purpose Dynamic chest radiography (DCR) is a flat‐panel detector (FPD)‐based functional lung imaging technique capable of measuring temporal changes in radiographic lung density due to ventilation and perfusion. The aim of this study was to determine the diagnostic performance of DCR in the evaluation of pulmonary function based on changes in radiographic lung density compared to nuclear medicine lung scans. Methods This study included 53 patients with pulmonary disease who underwent DCR and nuclear medicine imaging at our institution. Dynamic chest radiography was conducted using a dynamic FPD system to obtain sequential chest radiographs during one breathing cycle. The maximum change in the average pixel value (Δ max ) was measured, and the percentage ofΔ max in each lung region, calculated relative to the sum of all lung regions (Δ max %), was calculated for each factor (ventilation and perfusion). The Δ max % was compared with the accumulation of radioactive agents (radioactive agents%) on ventilation and perfusion scans in each lung and lung region using correlation coefficients and scatter plots. The ratio of ventilation to perfusion Δ max % was calculated and compared with nuclear medicine ventilation‐perfusion (V/Q) findings in terms of sensitivity and specificity for V/Q mismatch in each lung region. Results There was a high correlation between Δ max % and radioactive agents% for each lung (Ventilation: r = 0.81, perfusion: r = 0.87). However, correlation coefficients were lower (0.37 to 0.80) when comparing individual lung regions, with the upper lung regions showing the lowest correlation coefficients. The sensitivity and specificity of DCR for V/Q mismatch were 63.3% (19/30) and 60.1% (173/288), respectively. Motion artifacts occasionally increased Δ max %, resulting in false negatives. Conclusions Ventilation and perfusion Δ max % correlated reasonably with radioactive agents% on ventilation and perfusion scans. Although the regional correlations were lower and the detection performance for V/Q mismatch was not enough for clinical use at the moment, these results suggest the potential for DCR to be used as a functional imaging modality that can be performed without the use of radioactive contrast agents. Further technical improvement is required for the implementation of DCR‐based V/Q studies.
23
Respiratory physiology: The essentials
British Journal of Diseases of the Chest · 1975 · 1.1K citations
RESPIRATORY PHYSIOLOGY-THE ESSENTIALS,
Gary Brooks · Cardiopulmonary Physical Therapy Journal · 1995 · 408 citations
Marika Bajc, C. Schümichen, Thomas Grüning et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2019 · 227 citations · Full text