Magnetic Resonance in Medicine · 2020 · 24 citations · 37 references
Natural SciencesBiomedical EngineeringPhysicsBiomedical ImagingDiagnostic ImagingMedical PhysicsCardiac ImagingCardiac PhysiologyCardiovascular ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMagnetic Resonance Signal FormationB0 Field Inhomogeneity CorrectionField HomogeneityMagnetic Field HomogeneityMagnetic Field InhomogeneityMagnetic Field ShimmingRegion Of Interest SelectionStatic Magnetic FieldStatic Magnetic Susceptibility
Purpose Inhomogeneities of the static magnetic B 0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B 0 ‐field inhomogeneities, and their homogenization (B 0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B 0 variations are measured, and a methodology for spherical harmonics shimming of the B 0 field within the human myocardium is proposed. Methods The spatial B 0 ‐field distribution in the heart was analyzed as well as temporal B 0 ‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B 0 shimming were evaluated by calibration‐based B 0 ‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming. Results The strongest B 0 ‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B 0 ‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B 0 ‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents. Conclusion Challenges in state‐of‐the‐art B 0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.
37
Cardiac SSFP imaging at 3 Tesla
Michael Schär, Sebastian Kozerke, Stefan Fischer et al. · Magnetic Resonance in Medicine · 2004 · 306 citations
Human cardiac imaging at 3 T using phased array coils
Ralph Noeske, F. Seifert, K. H. Rhein et al. · Magnetic Resonance in Medicine · 2000 · 163 citations · Full text