Correlation between the Monitoring Data of a Photovoltaic Power Plant and Module Defects Detected by Drone-Mounted Thermography

Manuel Dalsass, H. Scheuerpflug, Martin Maier, Christoph J. Brabec

EU PVSEC · 2015 · 11 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Recently, drone-based aerial thermography has become a convenient quality assessment tool for the precise localization of defective modules and cells in a large photovoltaic power plant. However, thermographic recordings cannot be utilized for a quantitative estimation of the overall power generation of a solar park yet. In this context, a solar generator with a nominal power of approximately 2.36 MWp and 10,500 modules was examined using drone-based aerial thermography. The subsequent analysis of both the recorded radiometric data as well as the monitoring data of the inverters indicates a strong correlation between defective modules and the current generated in the associated string. Moreover, a cost-benefit calculation reveals that the cumulative effect of all found defective modules can result in a noticeable deficiency of receipts for both operators and investors. The results of this work will advance future automatic monitoring and early detection systems.