NMR in Biomedicine · 2020 · 56 citations · 66 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiovascular ImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMagnetic Resonance Pulse SequencesMedical Imaging3D Magnetic Resonance ImagingMagnetic Resonance Fingerprinting ReconstructionMr FingerprintingMyocardial Tissue CharacterizationRespiratory Motion CompensationRespiratory Motion CorrectionSpin EchoSpin Echo Imaging
Purpose To develop a novel respiratory motion compensated three‐dimensional (3D) cardiac magnetic resonance fingerprinting (cMRF) approach for whole‐heart myocardial T 1 and T 2 mapping from a free‐breathing scan. Methods Two‐dimensional (2D) cMRF has been recently proposed for simultaneous, co‐registered T 1 and T 2 mapping from a breath‐hold scan; however, coverage is limited. Here we propose a novel respiratory motion compensated 3D cMRF approach for whole‐heart myocardial T 1 and T 2 tissue characterization from a free‐breathing scan. Variable inversion recovery and T 2 preparation modules are used for parametric encoding, respiratory bellows driven localized autofocus is proposed for beat‐to‐beat translation motion correction and a subspace regularized reconstruction is employed to accelerate the scan. The proposed 3D cMRF approach was evaluated in a standardized T 1 / T 2 phantom in comparison with reference spin echo values and in 10 healthy subjects in comparison with standard 2D MOLLI, SASHA and T 2 ‐GraSE mapping techniques at 1.5 T. Results 3D cMRF T 1 and T 2 measurements were generally in good agreement with reference spin echo values in the phantom experiments, with relative errors of 2.9% and 3.8% for T 1 and T 2 ( T 2 < 100 ms), respectively. in vivo left ventricle (LV) myocardial T 1 values were 1054 ± 19 ms for MOLLI, 1146 ± 20 ms for SASHA and 1093 ± 24 ms for the proposed 3D cMRF; corresponding T 2 values were 51.8 ± 1.6 ms for T2‐GraSE and 44.6 ± 2.0 ms for 3D cMRF. LV coefficients of variation were 7.6 ± 1.6% for MOLLI, 12.1 ± 2.7% for SASHA and 5.8 ± 0.8% for 3D cMRF T 1 , and 10.5 ± 1.4% for T2‐GraSE and 11.7 ± 1.6% for 3D cMRF T 2 . Conclusion The proposed 3D cMRF can provide whole‐heart, simultaneous and co‐registered T 1 and T 2 maps with accuracy and precision comparable to those of clinical standards in a single free‐breathing scan of about 7 min.
66
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text
Learning a variational network for reconstruction of accelerated MRI data
Kerstin Hammernik, Teresa Klatzer, Erich Kobler et al. · Magnetic Resonance in Medicine · 2017 · 1.7K citations
Daniel Messroghli, James Moon, Vanessa M. Ferreira et al. · Journal of Cardiovascular Magnetic Resonance · 2016 · 1.7K citations · Full text
Medicine, Cardiology, Radiology +17