Radiation Detection Technology and Methods · 2020 · 66 citations · 7 references
EngineeringNuclear EngineeringInstrumentationMetrologyNuclear InstrumentationDetector SystemsSystem MonitoringEnergy Data CollectionEnergy MonitoringOnline MonitoringOnline Monitoring SystemsReal-time Data MonitoringReal-time MonitoringReal-time Processing
Abstract Background Data Quality Monitoring system (DQM) was developed to monitor data quality at BESIII experiment in real time. The stable center-of-mass energy ( $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> ) is essential for the data taking. Online monitoring the $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> can help find the beam energy shift in time. Purpose The purpose is to monitor the $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> in DQM system in real time. Methods The $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> is measured using Bhabha scattering process in DQM system, due to its large cross section and low background level. The $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> is calculated from the invariant mass of $$e^{+}e^{-}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msup> <mml:mi>e</mml:mi> <mml:mo>+</mml:mo> </mml:msup> <mml:msup> <mml:mi>e</mml:mi> <mml:mo>-</mml:mo> </mml:msup> </mml:mrow> </mml:math> , and the correction value from radiation effect and momentum calibration. Result The $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> calculated with DQM system shows a good consistency with that from offline reconstruction within error. The results are validated with data taken in 2013. The overall systematic uncertainty includes 0.39 MeV/c $$^2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mrow/> <mml:mn>2</mml:mn> </mml:msup> </mml:math> from signal extraction and 2.54 MeV/c $$^2$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msup> <mml:mrow/> <mml:mn>2</mml:mn> </mml:msup> </mml:math> from calibration and radiation correction. Conclusions The $$E_\mathrm{cms}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>E</mml:mi> <mml:mi>cms</mml:mi> </mml:msub> </mml:math> calculated from Bhabha scattering process is now available on DQM system in real time, which can be used as references for researchers to operate BESIII experiment.
7
Design and construction of the BESIII detector
Z. H. An, J. Z. Bai, J. M. Bian et al. · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2010 · 1.2K citations · Full text
Engineering, Electrical Engineering, Nuclear Engineering +12
BEPCII Performance and Beam Dynamics Studies on Luminosity
Chenghui Yu, Z. H. Duan, Shengdong Gu et al. · JACOW · 2016 · 281 citations · Full text
D. M. Asner, I. I. Bigi, Jérôme Charles et al. · International Journal of Modern Physics A · 2009 · 217 citations