Respirology · 2020 · 10 citations · 6 references
Veterinary MedicinePathologyRadiologyDiagnostic ImagingUltrasonographyUltrasoundDiagnostic UltrasonographyElastographyMediastinal ImagingThoracic UltrasonographyThoracic UltrasoundEnlarged Lymph NodesLung Cancer StagingLymph Node Assessment By UltrasoundMediastinal Lymph Node StagingMediastinal StagingSarcoid GranulomasStrain ElastographyUltrasound-based Staging
To the Editors: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), increasingly used for the pathological confirmation of the clinical suspect of sarcoidosis, has a 20% failure rate in the detection of granulomas.1-4 Clinical experience and anecdotal reports suggest that at least some of the non-diagnostic EBUS-TBNA in sarcoidosis may be caused by the presence of lymph nodes with extensive fibrosis.2, 5 We assessed the role of EBUS-strain elastography (EBUS-SE) in sarcoidosis patients enrolled in Nijmegen (The Netherlands) and Bologna (Italy) in the setting of the E-predict study. This was an international, multicentre prospective study aimed at assessing the reproducibility and the added clinical value of EBUS-SE in patients undergoing the procedure for mediastinal staging of lung cancer or suspected sarcoidosis (clinicaltrials.gov identifier: NCT02488928).6 All of the patients signed an informed consent. The EBUS procedures were carried out with a linear echobronchoscope (EB-1970UK and EB19-J10U; Pentax Medical, Tokio, Japan, Hitachi-Aloka: Zugo, Swizerland) in combination with a standalone ultrasound processor (Hitachi Preirus; Hitachi-Aloka Medical Ltd, Japan), and the aspirations were performed with dedicated 22-gauge needles (ECHO-HD-22-EBUS-P; Cook Medical Inc., USA). Strain elastography was assessed with the mean value of the strain histogram.7 Rapid on-site cytological evaluation was available for every EBUS procedure at both enrolling centres. The EBUS samples obtained from each lymph node in patients finally diagnosed with sarcoidosis were reviewed by a single experienced pulmonary pathologist (A.C.) blinded to the clinical and radiological details. For each individual slide, the pathologist registered the adequacy (representativeness of lymph node tissue) and the number (if any) of granulomas. Then, the above-mentioned counts from slides belonging to each lymph node station were then combined to determine the proportion of inadequate slides (number of inadequate slides/total number of slides from that specific lymph node station) and the proportion of slides with granulomas (number of slides with at least one granuloma/total number of slides from that specific lymph node station). We correlated the lymph node strain histogram mean with both the proportion of inadequate slides (primary endpoint) and the proportion of slides with granulomas (secondary endpoint) on a per-lymph node basis. Furthermore, possible differences in the above-mentioned endpoints according to the sarcoidosis pattern at computed tomography (CT; lymphadenopathy alone vs lymphadenopathy with parenchymal disease) were explored. Categorical variables are expressed as numbers and percentages. Quantitative variables are described as mean and SD, if normally distributed (Shapiro–Wilk test) or as median and interquartile range otherwise. Being not normally distributed, associations between mean strain histogram and proportion of inadequate slides or proportion of slides with granulomas were evaluated with the Spearman's rank correlation coefficient. The magnitude of an effect size for correlation coefficients was evaluated as described by Cohen: small for correlation coefficients on the order of 0.1, medium for those on the order of 0.3 and large for those on the order of 0.5. In our study, we considered a correlation coefficient of greater than 0.3 significant, in line with many correlation coefficients reported in the literature.8 A Student's t-test (two-sided, 95% CI) was used to compare means of normally distributed variables according to the CT pattern of disease. Forty-six lymph nodes (mean size: 13.6 mm, stage I: 29 nodes) from 33 sarcoidosis patients (mean age: 49 years, females: 20, stage I: 20) were sampled and evaluated. The average of the mean strain histogram in the whole lymph node cohort was 69.9 (range: 17–146). We found a statistically significant negative correlation between strain histogram mean and the proportion of inadequate slides (Spearman's ρ: −0.430, P = 0.002), but not between strain histogram mean and the proportion of slides with granulomas (Spearman's ρ: 0.184, P = 0.22). The proportion of slides with granulomas was significantly higher in stage I than in stage II (52% vs 37%, P = 0.05), whereas the proportion of inadequate slides was not different (74% vs 68%, P = 0.51). The diagnostic yield for the detection of granulomas on a per-lymph node basis was 93.4% (43 of 46 lymph nodes). The average of the strain histogram mean in the three lymph nodes who lacked granulomas at EBUS was significantly lower than in the remaining 43 (43.9 vs 72.1, P = 0.040). Our study provides preliminary evidence that sampling lymph nodes characterized by low strain elastography, that is ‘stiff’ nodes, is associated with an increased risk of retrieving an inadequate sample (i.e. a sample that is not representative of the lymph node tissue). Importantly, it should be considered that the availability of rapid on-site evaluation (ROSE) for every EBUS procedure in our cohort might have even mitigated the magnitude of the above-mentioned association by contributing to the reduction of the amount of both inadequate, and possibly non-diagnostic samples. Although the lack of comparative studies with a surgical arm prevents us from getting a direct evidence that lymph nodes with low strain elastography are characterized by an increased amount of fibrosis in sarcoidosis, several indirect clues from our study and from the literature support this hypothesis. In our cohort, the strain histogram mean was significantly lower in lymph nodes that lacked granulomas at EBUS than in those that featured them. While the numbers involved are too small to allow for any definitive conclusions, this finding may indirectly strengthen the theory that ‘stiff’ nodes may have increased fibrotic content and few or no granulomas.2 Second, one ex vivo study has shown a clear correlation between strain elastography and the extent of fibrosis in abdominal lymph nodes of patients with Crohn's disease.9 Third, a recently published case report has shown the association between low strain as measured by a ‘blue’ colorimetric elastography pattern and the presence of a large amount of fibrotic strands and very few non-necrotizing granulomas encased in fibrosis in a patient with stage II sarcoidosis.5 Lastly, lymph nodes characterized by low strain at elastography typically offer a high level of resistance upon needle advancement during sampling,2 which in turn is strongly suggestive of fibrotic lymph node changes (Fig. 1). We found no difference in the proportion of inadequate slides in stage I versus stage II sarcoidosis, but patients with lymphadenopathy alone had a significantly higher proportion of slides with granulomas. This finding strengthens the hypothesis that lymph nodes of patients with stage I have a higher density of granulomas, a finding that might help explain the reason why EBUS-TBNA series commonly report higher diagnostic yields in this specific disease stage.2, 4 The use of a semiquantitative method to reliably assess EBUS-SE and the multicentric setting represent the strength of the present study. However, some key limitations need to be acknowledged. Besides the lack of a comparative surgical arm, the small sample size and the retrospective design are worth mentioning. Furthermore, the failure rate of EBUS-TBNA in our cohort was unusually low both on a per-lymph node basis (10%) and especially on a per-patient basis (0%). The excellent diagnostic success we obtained, which pose problems regarding their external validity, may have at least two explanations. The large experience of interventional pulmonologist and pathologist in the tertiary referral centres involved in the study might certainly be one of them. Furthermore, the availability of ROSE for every EBUS procedure may have positively affected the diagnostic success.10 It is likely that the operators kept sampling their target lesions until the on-site pathologist provided a positive feedback on the presence of granulomas. Finally, we could not assess the possible influence of the use of large bore needles (19-gauge) on the adequacy of the samples in lymph nodes with low strain as no such needles are currently available for use with the Pentax echobronchoscope. In conclusion, this pilot study provides preliminary evidence that EBUS-SE suggesting lymph node stiffness—a likely surrogate of the extent of fibrosis—is significantly associated with increased inadequacy rate of EBUS-TBNA specimens in sarcoidosis. Having this information beforehand, the operator may decide to pursue additional sampling procedures (transbronchial biopsy and endobronchial biopsy) to reduce the likelihood of diagnostic failure, especially if ROSE is unavailable or is inconclusive. Conceptualization: R.T., A.C., E.H.F.M.V.d.H. Data curation: R.T., R.L.J.V., A.D.S., F.N. Formal analysis: R.L.J.V., A.D.S. Investigation: R.T., R.L.J.V., A.C., F.N., E.H.F.M.V.d.H. Methodology: R.T., R.L.J.V., A.C., E.H.F.M.V.d.H. Software: R.L.J.V., A.D.S. Supervision: R.L.J.V., E.H.F.M.V.d.H. Validation: A.D.S. Writing—original draft: R.T. Writing—review and editing: R.L.J.V., A.C., F.N., E.H.F.M.V.d.H. Visual Abstract Role of EBUS strain elastography in sarcoidosis lymphadenopathy. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
6