Brazilian Dental Science · 2020 · 12 citations · 11 references
DentistryDental Materials ScienceProsthodonticsDental MaterialsMechanical Properties Of Dental MaterialsProsthodontic MaterialsDenture RetentionDenture Teeth MaterialsMaterials For Maxillofacial ProsthesesRemovable Partial Denture DesignStrength PropertiesTensile PropertiesChewing Simulator TestingFatigue ResistanceMechanical Fatigue ResistancePartial Denture BiomechanicsRemovable Partial Denture FabricationRetention BiomechanicsRetentive StrengthThermoplastic Processing
Objective: was to evaluate the retentive force, fatigue resistance and deformity of clasps made from two materials cobalt chromium and poly ether et her ketone (PEEK). Material and Methods: sixteen models were fabricated, each one having lower 1st molar. Models were divided into two groups according to materials, group I (GI) for cobalt chromium (Co-Cr) and group II (GII) for PEEK. Each testing models and its clasps were mounted inside universal testing machine, the retention was measured by applying withdrawal force to it by this machine at 5 mm/min. The Fatigue resistance is measured by the reduction in retention through repeated insertion and removal cycles using robot a chewing simulator. Removal and insertion cycling of clasps was carried out for 360, 730, 1080, 1,440,2,116 and 2,880 cycles (corresponding to 3,6,9,12, 18 and 24 months of simulated clinical use of a RPD) to simulate the fatigue resistance test. Deformity was measured before and after each cycling using a digital micrometer. Statistical analysis was done by 2-way-ANOVA test to detect significance effects of each variable. Results: Retention and fatigue resistance, after 360,730, 1080, 1,440,2,116 and 2,880 cycles totally the difference between Co-Cr and PEEK groups was statistically non-significant (P = 0.0980>0.05) where (Co-Cr > PEEK). Deformation results, regardless to evaluation time, Co-Cr group recorded statistically significant higher deformation mean value than PEEK group (P = 0.008<0.05). Regardless to material group, deformation mean value changed non significantly by time (P = 0.2882> 0.05). Conclusion: PEEK clasps (1.0 mm in cross section diameter) engage 0.50 mm undercut provide sufficient retention nearly similar that of Co-Cr clasps.KeywordsFlexible clasps; Polyether ether ketone, PEEK; Thermoplastic resin; Partial denture.
11
Panagiotis Zoidis, Ioannis Papathanasiou, Gregory Polyzois · Journal of Prosthodontics · 2015 · 280 citations
Retentive forces and fatigue resistance of thermoplastic resin clasps
Fahed Tannous, Martin Steiner, Ramez Shahin et al. · Dental Materials · 2011 · 231 citations · Full text
Natural Sciences, Materials Engineering, Materials Science +15
Renata Cristina Silveira Rodrigues, Ricardo Faria Ribeiro, Maria da Glória Chiarello de Mattos et al. · Journal of Prosthetic Dentistry · 2002 · 95 citations