BMJ Open Respiratory Research · 2020 · 81 citations · 1 references
MedicineInfectious DiseasesRespiratory TherapyCritical Care Respiratory TherapyPulmonary Function TestingPulmonologyBreathing SupportContinuous Positive Airway PressureMechanical VentilationPositive Airway Pressure TherapyRespiratory DiseaseRespiratory Failure ManagementCase Series ReviewMechanical Ventilation ManagementWeaning From Continuous Positive Airway Pressure
The aim of this case series is to describe and evaluate our experience of continuous positive airway pressure (CPAP) to treat type 1 respiratory failure in patients with COVID-19. CPAP was delivered in negative pressure rooms in the newly repurposed infectious disease unit. We report a cohort of 24 patients with type 1 respiratory failure and COVID-19 admitted to the Royal Liverpool Hospital between 1 April and 30 April 2020. Overall, our results were positive; we were able to safely administer CPAP outside the walls of a critical care or high dependency unit environment and over half of patients (58%) avoided mechanical ventilation and a total of 19 out of 24 (79%) have survived and been discharged from our care.
1
[Thoughts and practice on the treatment of severe and critical new coronavirus pneumonia].
Haichao Li, Jing Ma, Hong Zhang et al. · PubMed · 2020 · 14 citations