Oscillatory potentials in electroretinograms of the human macular region.

Yoshihiro Miyake, N Shiroyama, Ichiro Ota, Masayuki Horiguchi

PubMed · 1988 · 60 citations · 14 references

Concepts

Abstract

Using focal stimuli, we successfully recorded oscillatory potentials (OPs) in electroretinograms of the macular regions of 72 normal volunteers. The OPs consisted of three to four wavelets with a mean peak interval of approximately 6.5 msec, consistent with that recorded with conventional full-field stimuli over the entire retina. The changes of amplitude in response to the spot sizes and ring stimuli suggested that the distribution of OPs is different from that in a- and b-waves in human macular region.

References

14