Has Invisalign improved? A prospective follow-up study on the efficacy of tooth movement with Invisalign

Nada Haouili, Neal D Kravitz, Nikhilesh R. Vaid, Donald J. Ferguson, Laith Makki

American Journal of Orthodontics and Dentofacial Orthopedics · 2020 · 427 citations · 23 references

DOIFull text

Open access

Concepts

TL;DR

The study aimed to update the accuracy of tooth movement with Invisalign by prospectively evaluating 38 patients treated with Invisalign Full or Teen. The study measured all teeth from central incisor to second molar on digital intraoral scans, superimposing initial and final ClinCheck models to determine predicted and achieved values, and performed best‑fit analysis with Compare software. Intraoral scan analysis showed an overall mean accuracy of 50%, with buccal‑lingual crown tip at 56% and rotation at 46%; notably low accuracies were observed for mesial rotation of the mandibular first molar (28%), distal rotation of the maxillary canine (37%), and intrusion of the mandibular incisors (35%), indicating that while overall accuracy improved, the relative strengths and weaknesses of Invisalign tooth movement persisted.

Abstract

The purpose of this research was to provide an update on the accuracy of tooth movement with Invisalign (Align Technology, Santa Clara, Calif).This prospective clinical study included 38 patients treated with Invisalign Full or Invisalign Teen. All teeth, from the central incisor to the second molar, were measured on digital models created from intraoral scans. Predicted values were determined by superimposing the initial and final ClinCheck models, and achieved values were determined by superimposing the initial ClinCheck models and the digital models from the posttreatment scans. Individual teeth were superimposed with a best-fit analysis and measured using Compare software (version 8.1; GeoDigm, Falcon Heights, Minn). The types of tooth movements studied were a mesial-distal crown tip, buccal-lingual crown tip, extrusion, intrusion, and mesial-distal rotation.The mean accuracy of Invisalign for all tooth movements was 50%. The highest overall accuracy was achieved with a buccal-lingual crown tip (56%), whereas the lowest overall accuracy occurred with rotation (46%). The accuracies for mesial rotation of the mandibular first molar (28%), distal rotation of the maxillary canine (37%), and intrusion of the mandibular incisors (35%) were particularly low.There was a marked improvement in the overall accuracy; however, the strengths and weaknesses of tooth movement with Invisalign remained relatively the same.

References

23