Head & Neck · 2020 · 17 citations · 2 references
MedicineDiagnostic SciencesMucosal Drug DeliveryPulmonologyRhinologyNasal ExaminationRespiratory HygieneDroplet FormationDroplet Formation MechanismsMucus PhysiologyMucus RetentionNasal DropsNasal SpraysPersonal Protective Equipment
Respiratory particle generation and dispersal during nasoendoscopy and swab testing is studied with high-speed video and laser light illumination. Video analysis reveals droplet formation in three manoeuvres during nasoendoscopy - sneezing, vocalization, and nasal decongestion spray. A capillary bridge of mucus can be seen when a nasoendoscope exits wet nares. No droplet formation is seen during oral and nasopharyngeal swab testing. We outline the following recommendations: pull the face mask down partially and keep the mouth covered, only allowing nasal access during nasoendoscopy; avoid nasal sprays if possible; if nasal sprays are used, procedurists should be in full personal protective equipment prior to using the spray; withdrawal of swabs and scopes should be performed in a slow and controlled fashion to reduce potential dispersion of droplets when the capillary bridge of mucus breaks up.
2
Detection of SARS-CoV-2 in Different Types of Clinical Specimens
Yanli Xu, Ruqin Gao, Roujian Lu et al. · JAMA · 2020 · 5.3K citations · Full text