European Heart Journal · 2020 · 169 citations · 27 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyVascular SurgeryAortic SurgeryCardiac Valve SurgerySurgical Valve ReplacementSurvival OutcomesTranscatheter Aortic Valve ReplacementTranscatheter Valve TherapyAortic Valve Disease PrognosisBioprosthetic Heart ValvesBioprosthetic Valve DegenerationBioprosthetic Valve DysfunctionBioprosthetic Valve FailureBioprosthetic Valve ProsthesesProsthetic Valve ManagementValve-in-valve Therapy
AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.
27
Helmut Baumgartner, Judy Hung, Javier Bermejo et al. · Journal of the American Society of Echocardiography · 2017 · 1.3K citations · Full text
Medicine, Cardiology, Radiology +17
James Brown, Sean M. O’Brien, Changfu Wu et al. · Journal of Thoracic and Cardiovascular Surgery · 2009 · 937 citations · Full text
Medicine, Cardiology, Surgery +14
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Danny Dvir, John G. Webb, Sabine Bleiziffer et al. · JAMA · 2014 · 906 citations · Full text
Medicine, Cardiology, Surgery +17