Comparison of diagnostic performance between quantitative flow ratio, non-hyperemic pressure indices and fractional flow reserve

Ojas Hrakesh Mehta, Michael Hay, Ren Yik Lim, Abdul Rahman Ihdayhid, Michael Michail, Jun Michael Zhang, James D. Cameron, Dennis Wong

Cardiovascular Diagnosis and Therapy · 2020 · 11 citations · 42 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: , neither QFR nor DILEMMA score require pressure wires. This study sought to compare the diagnostic performance of QFR, diastolic indices and DILEMMA score to predict FFR. METHODS: Between January 2010 and December 2013, patients who underwent invasive coronary angiography and FFR assessments were retrospectively studied. iFR and dPR were derived from FFR pressure tracings. QFR was computed using commercial software. RESULTS: 0.770, P<0.01). CONCLUSIONS: QFR had excellent correlation and accuracy as measured against FFR. When compared to other diastolic indices and DILEMMA score, QFR performed at least as well as the other indices. QFR predicts FFR better than it predicts iFR. QFR is a convenient tool to assess significance of coronary stenosis and a reliable alternative to pressure-wire based indices. Prospective studies are required to investigate the performance and cost-effectiveness of QFR when independently used to guide clinical decision making.

References

42